Introduction
A plasma autoclave is an autoclave that uses the low-temperature plasma for the sterilization of the heat-sensitive instruments and the materials, and it is used in the medical, the dental, the clinical, and the many other applications. The plasma autoclave sterilizes the instruments by the generation of the low-temperature hydrogen peroxide plasma, which inactivates the microorganisms, at the temperatures below 60 degrees Celsius, and it is suitable for the heat-sensitive instruments; the plasma autoclave consists of a sterilization chamber, a vacuum system, a hydrogen peroxide vapor delivery system, a plasma generator, and the controls, and it provides the sterilization cycles, with features such as the temperature monitoring and the cycle recording; the plasma autoclave is used for the sterilization of the endoscopic instruments, the electronic instruments, the delicate surgical instruments, and the other heat-sensitive materials, for the medical and the dental applications, for the research, and for many other applications, and it is an essential equipment for the low-temperature sterilization. Plasma autoclaves are used in the hospitals, in the dental clinics, in the clinical laboratories, in the research, and for many other applications. With their low-temperature plasma, plasma autoclaves are essential for the sterilization of the heat-sensitive instruments.
Plasma Autoclave LPA-T2012
Plasma Autoclave has a capacity of 160L, providing enough space to sterilize multiple medical instruments at once. The sterilizing temperature is maintained at 50 ± 5℃, which is safe f...
Plasma Autoclave LPA-T2011
Plasma Autoclave has a capacity of 135 litres and offers sterilization at temperatures below 55°C. It is equipped with advanced a powerful high-vacuum system that enhances plasma penetr...
Plasma Autoclave LPA-T2012
Plasma Autoclave has a capacity of 190 litres and offers sterilization at temperatures below 55°C. It takes 60 minutes for sterilization of hollow or tubular instruments requiring deep ...
Plasma Autoclave LPA-T2010
Plasma Autoclave uses H2O2 plasma technology and offers sterilization at temperatures below 55°C. It features a user-friendly 7-inch touch screen interface, providing real-time monitori...
Plasma Autoclave LPA-T2010
Plasma Autoclave is a fully automatic system with an 80L capacity. It operates at a low sterilization temperature of 50°C ± 5°C. It employs a cassette system with 12 vials of 60% H2O2...
Plasma Autoclave LPA-T2011
Plasma Autoclave has a sterilization chamber with a capacity of 135L. It operates at temperatures between 40℃ and 60℃, using 58% to 60% hydrogen peroxide as the sterilizing agent. This...
Plasma Autoclave LPA-T2010
Plasma Autoclave features a 110-liter chamber made from stainless steel 304, ensuring durability. It offers multiple sterilization cycles at 50℃ ± 5℃. A rotary vane vacuum pump ensure...
Plasma Autoclave LPA-T2012
Plasma Autoclave has a chamber volume of 300 liters and operates at a sterilization temperature of 50 ± 5°C.It features a rectangular design made from alloy materials for good thermal ...
Plasma Autoclave LPA-T2011
Plasma Autoclave sterilizes at a temperature of 50 ± 5°C within a chamber volume of 180 liters. It features cassettes that hold 12 vials of hydrogen peroxide each for efficient operati...
Plasma Autoclave LPA-T2013
Plasma Autoclave comes with an 80L chamber size for efficient and versatile sterilization. It operates at a sterilizing temperature of 50±5℃, ensuring precise and consistent performanc...
Plasma Autoclave LPA-T2010
Plasma Autoclave is a fully automatic sterilizer with a 128L capacity. It uses 60% hydrogen peroxide at a temperature range of 50 ± 5℃ for sterilization. This autoclave has a rectangul...
Plasma Autoclave LPA-T2030
Plasma Autoclave is a fully automatic sterilizer with a 60L capacity. It uses 60% hydrogen peroxide at a temperature range of 50 ± 5℃ for sterilization. An advanced vacuum pump ensures...
Plasma Autoclave LPA-T2012
Plasma Autoclave is a rectangular design that has a chamber volume of 200 liters. It is made from alloy materials for good thermal conductivity. Equipped with a high-efficiency H2O2 filt...
Plasma Autoclave LPA-T2011
Plasma Autoclave is a 120 Liters vertical single cycle sterilization unit. Equipped with H2O2 purification device with minimum 3 sterilization programmes. Real time monitorisation of ste...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Plasma autoclave for low-temperature sterilization using hydrogen peroxide plasma.
2. Low-temperature sterilization for heat- and moisture-sensitive medical instruments.
3. Suitable for hospitals, clinics, dental practices, surgical centers and laboratories.
4. Includes sterilization chamber, plasma generator, H2O2 delivery, control system.
5. Fast cycle time with no toxic residue for delicate instrument sterilization.
FAQ
Q1: What testing scenarios is this autoclave mainly applied to?
A: The plasma autoclave is used in hospitals, surgical centers, dental practices, clinics, ophthalmology facilities and medical device reprocessing departments to sterilize heat- and moisture-sensitive medical instruments and devices that cannot withstand traditional steam autoclaving. It supports sterilization of flexible endoscopes, surgical instruments with delicate components, ophthalmic instruments, dental instruments, electronic devices, lumened instruments and materials sensitive to high temperature or moisture. The hydrogen peroxide plasma process operates at low temperature, leaving no toxic residue and enabling fast turnaround of delicate instruments. It is essential for healthcare facilities, surgical centers, dental practices and medical device reprocessing requiring low-temperature sterilization for heat- and moisture-sensitive instruments, where traditional steam sterilization would damage delicate equipment, and where fast, residue-free, reliable sterilization is critical for patient safety, instrument protection, operational efficiency and regulatory compliance in healthcare, dental and clinical environments requiring sterilization of delicate, complex or heat-sensitive medical devices.
Q2: What standards does the autoclave comply with?
A: The plasma autoclave complies with relevant ISO, EN and GB/T standards for low-temperature sterilization equipment including ISO 14937, ISO 11135 for ethylene oxide (related), and applicable medical device regulations including FDA, CE and NMPA requirements. Sterilization efficacy follows ISO 14160 for single-use medical devices and applicable reprocessing standards. Safety standards for hydrogen peroxide handling apply. Cycle validation should be performed per applicable regulations.
Q3: What is the warranty period for the whole machine and key components?
A: The whole plasma autoclave is covered by a 12-month warranty. The chamber, plasma generator, vacuum system, H2O2 delivery and controller are covered, while filters, gaskets, cassettes and H2O2 cartridges are consumables or accessories. Damage from improper use, poor maintenance or unauthorized repair is excluded. Extended service contracts are standard for this critical medical equipment.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained sterile processing personnel familiar with low-temperature sterilization, instrument reprocessing and H2O2 safety. We provide comprehensive training, operation manuals and application support. Proper instrument cleaning and drying, loading, cycle selection, H2O2 handling and maintenance are essential for effective sterilization and safety.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular maintenance required? What is the recommended calibration cycle?
A: Comprehensive preventive maintenance per manufacturer schedule including vacuum system, plasma generator, H2O2 delivery and valve inspection. Filter and gasket replacement per schedule. H2O2 cartridge replacement per usage. Biological indicator testing per regulatory requirements (weekly or per load for critical items). Full cycle validation (PQ) annually or per regulations. Daily maintenance including chamber cleaning and leak check.
Q7: Are supporting consumables universal?
A: H2O2 cartridges or cassettes, filters, gaskets, biological indicators and test packs are available from the manufacturer or authorized distributors, though compatibility should be verified. Long-term consumable cost is significant for this sterilization method, with H2O2 consumables being the main recurring expense.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes chamber capacity, cycle types, H2O2 delivery system, control features, data logging and connectivity. Additional racks, trays and accessories can be ordered separately. Custom orders require specification and extend lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Yes, plasma autoclaves include on-site installation, commissioning, cycle validation, biological indicator testing and operator training by certified sterilization equipment specialists. Site preparation guidance is provided before delivery to ensure power, ventilation, drainage and safety requirements are met.
Q10: What types of instruments are compatible with this equipment?
A: The plasma autoclave sterilizes heat- and moisture-sensitive medical instruments and devices within the chamber capacity and material compatibility. Instruments must be thoroughly cleaned and dried before sterilization. Certain materials (cellulose, linen, liquids, some oils) are not compatible with hydrogen peroxide plasma sterilization. Lumened instruments may require specific lumen adapters or longer cycles. Users should follow manufacturer instructions for instrument compatibility, ensure proper cleaning and drying before sterilization, use appropriate packaging and loading, perform regular biological indicator testing, maintain H2O2 supply and ventilation, follow safety procedures for hydrogen peroxide handling, and validate cycles per regulatory requirements. Only instruments and materials validated for plasma sterilization should be processed, and the manufacturer IFU (instructions for use) should always be followed for each device type.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.