Introduction
Plasma Autoclave has a sterilization chamber with a capacity of 135L. It operates at temperatures between 40℃ and 60℃, using 58% to 60% hydrogen peroxide as the sterilizing agent. This autoclave uses pre-filled hydrogen peroxide cartridges for precise, automatic dosing. The system features a high-quality 5052 aluminum chamber and is controlled by a Siemens . Our Plasma Autoclave chamber door uses a jack-driven lift and light-sensing sensor for automatic, hands-free operation. It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Plasma Autoclave is widely used in and medical institutes for sterilizing electric wires, cables, optical glasses, power equipment, endoscopes, catheters, and other heat-sensitive instruments.Specifications
| Capacity | 135 L |
| Operating Temperature | 40°C to 60°C |
| Heating Method | Electric Heating |
| Sterilization Agent | 58% to 60% Hydrogen Peroxide |
| Display | 7- inch Touch Screen |
| Maximum Anti-Stress Value | 10 Pa |
| Operation Height | ≤160 cm |
| Total Cycle Time | Short cycle 30 min Long cycle 50 min |
| Material of Sterilization Room | 5052 Aluminum, Thickness ≥ 8 mm |
| Noise | < 60 db |
| Electrode Mesh Material | 5052 Aluminum Alloy, Thickness ≥ 2 mm |
| Sealing Door Material | 5052 Aluminum Alloy, Thickness ≥ 15 mm |
| Loading Method | Upper and lower aluminum alloy punching plates |
| Door Opening Method | Jack-driven electric lifting door, light-sensing infrared sensor switch |
| Door Anti-Pinch Function | Door barrier switch |
| Cavity Temperature Heating Power | Preheating time ≤30 min |
| Main Insulation | ≥20 mm Rubber and Plastic Sponge |
| Installation Environment | 10°C to 40 °C |
| Door Type | Automatic vertical single door |
| Standard Sterilization Time | 35 to 55 min |
| Data Storage | Stores and records data for 500 cycles |
| Air Filter | ≤ 0.22μm |
| Plasma Power Supply | Transistor control, ≤ 800W power |
| Power | 4.2 |
| Power Supply | AC 220V, 50Hz |
| Packaging Dimension | 1220 × 920 × 2720 mm |
| Chamber Size | 1120 × 790 × 1770 mm |
| Outer Size | 750 × 440 × 400 mm |
| Net Weight | 272 Kg |
| Gross Weight | 362 Kg |
Features
Cartridge filling method
7-inch touchscreen
Thermal printer
Biological indicator
Sensors and Alarm System
Oil mist filtration system
Evacuation Control Valve
FAQs
1. What is the recommended sterilization cycle for different types of laboratory materials?
The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.
2. How to properly load the autoclave to ensure effective sterilization?
Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.
3. What maintenance procedures are required for the autoclave?
Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.
4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?
If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.
5. What safety precautions should be followed when operating the autoclave?
Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.