Introduction
Jacketed Glass Reactor has a 0.5 L capacity and features a compact design. It is built to withstand high temperatures offering low thermal expansion, providing strong corrosion resistance. The unit includes a spiral condenser that ensures an efficient and wide cooling area. Equipped with stepless speed control, it allows smooth and precise adjustment of stirring speed. This reactor is suitable for use in chemical, biopharmaceutical, food, agricultural, and aerospace research and industrial applications.
This laboratory glass reactor is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Jacketed Glass Reactor is used for chemical synthesis, biopharmaceutical research, material development, food processing, agricultural studies, and aerospace applications in both laboratory and industrial environments.
Specifications
| Reactor Volume | 0.5 L |
| Jacket Volume | 0.4 L |
| Operating Temperature Range | -80°C to 200°C |
| Reactor Pressure | -0.1 to 0.0 Mpa |
| Jacketed Pressure | Less than or equal to ±0.03 Mpa |
| Rotation Speed Range | 0 to 1000 rpm |
| Pressure Equalizing Volume | 0.25 L |
| Recovery Head Volume | 0.25L |
| Speed Control Mode | Stepless speed regulation |
| Glass Material | High borosilicate 3.3 |
| Frame Material | SUS304 |
| Sealing Parts Material | Fluororubber |
| Stirrer Sealing Type | Skeleton oil seal |
| Agitator Blade | Stainless steel material with outer layer, paddle agitator |
| Kettle Temperature Difference Limit | Less than or equal to 80°C |
| Ambient Temperature Range | 5°C to 35°C |
| Relative Humidity | Less than or equal to 65% |
| Power Consumption | 90 W |
| Power Supply | 220V/50Hz,1P |
| Condenser Area | 0.05 Square Meters |
| Dimension | 380×380×1200 mm |
Features
Transparent reaction chamber
Uniform heat distribution
Secure sealing
Bottom discharge valve
Organic solvent-resistant
Flange reactor lid
Superior airtightness
FAQs
1. What are the key factors to consider when selecting this laboratory glass reactor for laboratory use?
When selecting this laboratory glass reactor, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this laboratory glass reactor be calibrated to ensure accurate results?
It is recommended to calibrate this laboratory glass reactor at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this laboratory glass reactor?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this laboratory glass reactor be used with different types of samples, and are there any compatibility considerations?
Yes, this laboratory glass reactor can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the laboratory glass reactor malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.