Introduction

Inductively Coupled Plasma Mass Spectrometers (ICP-MS) are built for ultra-trace detection and accurate analysis of elements in complex samples. They utilize argon plasma ionization to enable high-sensitivity detection at trace and ultra-trace levels. Their ETP double-mode detectors and advanced signal processing ensure precise, repeatable measurements. These systems support stable calibration and flexible sampling for diverse analytical tasks. Ideal for trace element analysis in nuclear monitoring, environmental testing, and material science research.

暂无信息

Standards

EPA Method 6020B-Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

Complies with the above standards, but is not limited to them.

Features

1. Data export and audit-trail options support laboratory records.

2. Automated sample handling improves throughput and repeatability.

3. High-resolution optics resolve closely spaced spectral lines.

4. Software provides method setup, calibration and reporting.

5. Safety interlocks protect against plasma and RF hazards.

FAQ

What are the main applications of the Inductively Coupled Plasma Mass Spectrometry?

The Inductively Coupled Plasma Mass Spectrometry is used for elemental analysis of samples by inductively coupled plasma, identifying and quantifying metals and trace elements. It supports environmental, geological, metallurgical, pharmaceutical and food laboratories requiring multi-element detection.

What standards does the Inductively Coupled Plasma Mass Spectrometry comply with?

The instrument is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for analytical instruments, with methods following applicable elemental-analysis standards. Compliance documentation can be provided on request.

What does the warranty cover?

The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.

Will staff need special training?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Inductively Coupled Plasma Mass Spectrometry be calibrated?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Are the consumables universal or proprietary?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can the Inductively Coupled Plasma Mass Spectrometry be customised?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.

What should be avoided when using the Inductively Coupled Plasma Mass Spectrometry?

Do not introduce incompatible or high-solids samples without proper preparation, and handle argon and plasma safely. Follow sample digestion and laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.