Introduction

Inductively coupled plasma mass spectrometry (ICP-MS) is an analytical technique used for the sensitive and the multi-element analysis of the trace elements in the samples, and it is used in the environmental, the clinical, the food, the geological, the semiconductor, and the many other applications. In the ICP-MS, the sample is introduced into the inductively coupled plasma, in which the elements are atomized and ionized, and the ions are introduced into the mass spectrometer, in which they are separated by the mass-to-charge ratio and detected, and the technique provides the high sensitivity for the trace and the ultra-trace elements; the ICP-MS system consists of a sample introduction system, an inductively coupled plasma source, an interface, a mass analyzer, such as the quadrupole, a detector, and a data system, and it provides features such as the multi-element analysis, the isotopic analysis, and the low detection limits; the ICP-MS is used for the analysis of the trace metals in the water and the environmental samples, for the analysis of the biological samples, for the analysis of the foods, for the analysis of the geological samples, for the analysis of the semiconductor materials, and for many other applications, and it is an essential analytical technique for the trace element analysis. ICP-MS systems are used in the environmental laboratories, in the clinical laboratories, in the food industry, in the geology, in the semiconductor industry, and for many other applications. With their high sensitivity, ICP-MS systems are essential for the trace element analysis.

Inductively Coupled Plasma Mass Spectrometer T-S210ICPMS

Inductively Coupled Plasma Mass Spectrometer T-S210ICPMS


Inductively Coupled Plasma Mass Spectrometer provides a mass range from 2 to 260 amu for precise analysis of trace elements. It utilizes argon plasma to ionize samples, ensuring high ioni...

Standards

EPA Method 6020B-Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

Complies with the above standards, but is not limited to them.

Features

1. Inductively coupled plasma mass spectrometer for ultra-trace elemental analysis.

2. ICP ion source with high-temperature plasma provides efficient ionization of most elements.

3. Quadrupole or high-resolution mass analyzer for sensitive and selective elemental detection.

4. Supports multi-element analysis of liquids, digested solids and slurries at ppb to ppt levels.

5. Suitable for environmental, semiconductor, clinical, geological and nuclear applications.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The ICP-MS system is used in environmental monitoring, semiconductor manufacturing, clinical research, geological exploration, nuclear analysis and food safety laboratories for ultra-trace multi-elemental analysis. It supports heavy metal testing in water and soil, trace impurity analysis in semiconductor materials, elemental analysis of biological fluids, mineral exploration and geochemical characterization, and radionuclide measurement. The exceptional sensitivity and multi-element capability make it the instrument of choice for applications requiring parts-per-billion or parts-per-trillion detection limits across the periodic table, where ICP-OES or AAS cannot achieve the required sensitivity.

Q2: What standards does the instrument comply with?

A: The system supports methods referenced in EPA 6020A for ICP-MS analysis, ISO 17294 for water quality, ASTM standards for specific matrices, and relevant GB/T standards for elemental analysis. The hardware complies with IEC 61010 laboratory safety standards. Electronic records may be configured for 21 CFR Part 11 compliance. Radiation safety complies with local regulations for RF equipment.

Q3: What is the warranty period for the whole machine and key components?

A: Standard warranty is 12 months from commissioning. The plasma source, mass analyzer, detector and vacuum system are covered, while cones, pumps, tubing and standards are consumables excluded from warranty. Extended warranty and service contracts are strongly recommended for this high-value system. Damage from improper sample introduction or lack of maintenance is excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: ICP-MS operation requires specialist training in plasma spectroscopy, mass spectrometry, sample preparation and interference correction. We provide structured operator training, application support and method consultation. Routine use by trained analysts is supported by software wizards, but method development and interference management require experienced personnel.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Calibration with multi-element standards should be performed before each analytical batch. Drift correction with internal standards is used during long sequences. Mass calibration and resolution verification should be performed per the manufacturer schedule. Annual preventive maintenance by a certified engineer is essential. Cones and torch should be inspected and cleaned regularly based on sample matrix and throughput.

Q7: Are supporting consumables universal? What about the long-term procurement cost?

A: Sample cones, skimmer cones, torches, tubing and pumps are available from the manufacturer or authorized distributors, though original consumables are recommended for optimal performance. Argon gas consumption is a significant ongoing cost. Calibration standards should be sourced from accredited providers. Long-term consumable, gas and service cost is substantial and should be included in the annual budget.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes mass analyzer type, collision cell technology, sample introduction system, autosampler and software modules. Custom orders require detailed application discussion and extend lead-time. Users should define target elements, concentration ranges, matrices and required detection limits before configuration.

Q9: Does the purchase include on-site installation and commissioning service?

A: Yes, ICP-MS systems include on-site installation, commissioning and operator training by a certified application specialist. Site preparation guidance is provided before delivery to ensure the laboratory meets power, argon supply, ventilation and environmental requirements.

Q10: What types of samples are compatible with this equipment?

A: The system analyzes liquid samples and digested solids within the element range and concentration limits. Samples must be properly digested, filtered and acidified to avoid clogging the nebulizer and cone. High total dissolved solids can cause matrix effects and cone deposition, requiring dilution or special sample introduction. Organic solvents may require oxygen addition or special configuration. Users should verify matrix compatibility and required sample preparation for each application.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.