Introduction

Plasma Autoclave features a 110-liter chamber made from stainless steel 304, ensuring durability. It offers multiple sterilization cycles at 50℃ ± 5℃. A rotary vane vacuum pump ensures efficient operation with high corrosion resistance. It includes a robust alarm system and biological monitoring. Our autoclave’s durable stainless-steel chamber and advanced control system make it safe sterilization in medical facilities.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Plasma Autoclave is widely used in or other medical institutes for the sterilization of electric wires and cables, optical glasses and glass lenses, power equipment and batteries, endoscopes, non-metallic catheters, and other wet or heat-sensitive instruments.

Specifications

Chamber Volume 110 L
Chamber material Stainless steel 304
Sterilization Agent 60% hydrogen peroxide
Sterilization Cycle Fast sterilization: ≤25min
Standard sterilization: ≤35min
Enhanced sterilization: ≤55min
Sterilization Temperature 50℃ ± 5℃
Filter Ultrafine sterile filter
Oil mist filter
Filling Method Cassette: 12 vials of H₂O₂ / cassette
New cassette: Automatic delivery
Used cassette: Automatic ejection
Loading Method 2 layers of aluminum alloy punching plate loaded with sterile items
Test Methods Biological monitoring of Bacillus subtilis and Bacillus stearothermophilus
Biological Indicator Cultivator Yes
Vacuum Pump Rotary vane vacuum pump with high vacuum degree
Evacuation rate: 16m³/h
Door Single door
Door Type Automatic vertical sliding door
Master Controller control
Display 7-inch color touchscreen
Printer Yes
Alarm System Equipped with high & low-temperature alarming system
Protective Function Various protective functions included
Power Consumption 2.8kW
Power Supply 110/220V, 50/60HZ
Internal Dimension 605 × 480 × 380 mm
External Dimension 790 × 780 × 1590 mm
Packaging Dimension 800 × 940 × 1780 mm
Net Weight 272 Kg
Gross Weight 302 Kg

Features

Low-temperature sterilization

Supports multiple cycles

Safe sealing door

Fully automatic control system

Advanced configuration

Corrosion resistance electromagnetic valve

FAQs

1. What is the recommended sterilization cycle for different types of laboratory materials?

The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.

2. How to properly load the autoclave to ensure effective sterilization?

Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.

3. What maintenance procedures are required for the autoclave?

Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.

4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?

If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.

5. What safety precautions should be followed when operating the autoclave?

Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.