Introduction

Plasma Autoclave comes with an 80L chamber size for efficient and versatile sterilization. It operates at a sterilizing temperature of 50±5℃, ensuring precise and consistent performance. The system uses 60% hydrogen peroxide, with cycle times ranging from 25 to 55 minutes. Its manual door and high-capacity vacuum pump ensure reliable and consistent operation. This autoclave is ideal for labs, hospitals, research, and pharmaceutical industries, ensuring fast, safe sterilization.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Plasma Autoclave is perfect for laboratories, hospitals, and medical facilities requiring precise sterilization. Its versatile design suits industries like pharmaceuticals and research for effective equipment sterilization.

Specifications

Chamber Volume 80L
Sterilization Temperature 50±5℃
Sterilizing Agent 60% Hydrogen Peroxide
Type Automatic
Sterilizing Time Fast sterilization cycle time: ≤25 min,
Working Pressure -60pa
Filling Method Cassette (1 cassette/12 vials 60% H2O2)
Loading Method 2 Shelves
Test Methods Bacillus subtilis, Bacillus stearothermophilus
Controller Control
Display 7-inch Color Touch Screen
Door Type Manual Door
Printer Yes
Biological Indicator Cultivator Yes
Vacuum Pump System Yes
Alarm System Yes (High & Low Temperature Alarms)
Chamber Material Aluminum alloy
Power Consumption 2.6kw
Power Supply 220V/50Hz
Chamber Dimension 610×350×350 mm
Outer Dimension 750×630×1500 mm
Packaging Dimension 880×760×1680mm
Net Weight 156 kg
Gross Weight 190 kg

Features

7-inch color touch screen display

Aluminum alloy chamber material

Easy-to-use control system

Built-in printer for data recording

Biodegradable hydrogen peroxide agent

Alarm system for safety alerts

Over-temperature protection system

Fast pre-heating within 30 minutes

High-quality aluminum alloy chamber material

FAQs

1. What is the recommended sterilization cycle for different types of laboratory materials?

The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.

2. How to properly load the autoclave to ensure effective sterilization?

Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.

3. What maintenance procedures are required for the autoclave?

Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.

4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?

If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.

5. What safety precautions should be followed when operating the autoclave?

Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.