Introduction
Vertical Pressure Steam Sterilizer has 100 L capacity ensuring effective steam sterilization for medical and laboratory materials. Their stainless steel chamber ensures durability and corrosion resistance. They feature automatic pressure control for consistent performance. Their digital display allows easy monitoring of pressure and time. Vertical Pressure Steam Sterilizer sterilizes laboratory glassware and medical waste.
Vertical Pressure Steam Sterilizer T-VS-S2104
Vertical Steam Sterilizer T-VS-L2103
Vertical Steam Sterilizer T-VS-L2101
Vertical Steam Sterilizer T-VS-L2102
Vertical Steam Sterilizer T-VS-L2100
Vertical Pressure Steam Sterilizer T-VS-S2103
Vertical Pressure Steam Sterilizer T-VS-S2102
Vertical Pressure Steam Sterilizer T-VS-S2101
Vertical Pressure Steam Sterilizer T-VS-S2100
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Vertical, horizontal and benchtop models suit various spaces.
2. Efficient vacuum pulses remove air from wrapped and hollow loads.
3. Over-pressure, over-temperature and low-water protection included.
4. Automatic air removal and drying improve sterilization results.
5. Stainless chamber resists corrosion and is easy to clean.
FAQ
What are the main applications of the Vertical Pressure Steam Sterilizer?
The Vertical Pressure Steam Sterilizer is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.
What standards does the Vertical Pressure Steam Sterilizer comply with?
The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.
What does the warranty cover?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
Will staff need special training?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.
Are the consumables universal or proprietary?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can it be adapted to our requirements?
A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.
Do you provide on-site installation?
Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.
What should be avoided when using the Vertical Pressure Steam Sterilizer?
Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.