Introduction

Plasma Autoclave is a fully automatic system with an 80L capacity. It operates at a low sterilization temperature of 50°C ± 5°C. It employs a cassette system with 12 vials of 60% H2O2, offering automatic delivery and ejection. This features an alloy chamber with excellent thermal conductivity and independent temperature control. The system has an electric lifting door with a double-layer seal and an anti-pinch design for enhanced safety. Our Plasma autoclave is safe and eco-friendly, with a high-efficiency H2O2 filter to prevent pollution.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Plasma Autoclave is widely used in and medical institutes for sterilizing electric wires, cables, optical glasses, power equipment, endoscopes, catheters, and other heat-sensitive instruments.

Specifications

Capacity 80 L
Type Fully automatic
Low Temperature Sterilization 50°C ± 5°C
Sterilization cycle Fast sterilization ≤25min
Standard sterilization ≤35min
Enhanced sterilization ≤55min
H2O2 Filling Method Cassette system: 12 vials of H2O2 per cassette
New cassette: automatic delivery
Used cassette: automatic ejection
Sterilization Agent High-purity H2O2 (60%)
Temperature control accuracy ≤ ± 0.3°C
Master Controller control
Display 7-inch color touchscreen
Optional Double door
Test methods Biological monitoring of Bacillus subtilis and Bacillus stearothermophilus
Door type Automatic vertical sliding door
Chamber material Rectangular alloy chamber with good thermal conductivity
Working temperature 50±5°C
Standard sterilization time 35 min
Vacuum 60 Kpa
Power supply 110/220V, 50/60Hz
Packaging Dimension 800 × 940 × 1780mm
Chamber Size 500 × 480 × 380 mm
Outer Size 790 × 780 × 1550 mm
Net Weight 260 Kg
Gross weight 298 Kg

Features

control system

Printer

Biological indicator cultivator

Power failure memory

Vacuum pump system

Alarm system

Oil mist filtration system

Advanced configuration

Imported pressure sensor

Convenient Installation

Electromagnetic Valve

FAQs

1. What is the recommended sterilization cycle for different types of laboratory materials?

The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.

2. How to properly load the autoclave to ensure effective sterilization?

Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.

3. What maintenance procedures are required for the autoclave?

Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.

4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?

If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.

5. What safety precautions should be followed when operating the autoclave?

Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.