Introduction
Digital Microscope features a viewing head with a compensation-free trinocular head, 30° inclined. It has a nosepiece with an inverted quintuple ball bearing revolving nosepiece. The microscope features a vibrant 9.7-inch window into the micro-world right at your fingertips. Our delivers razor-sharp, flat-field images with true-to-life color across all magnifications. This digital microscope is ideal for advanced research and clinical diagnostics in fields like cell biology and pathology.
This microscope is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Digital Microscope is ideal for advanced research and clinical diagnostics in fields like cell biology and pathology, providing high-resolution imaging for detailed sample analysis. Its integrated digital touchscreen and connectivity options also make it perfect for educational settings, allowing for easy demonstration and sharing of microscopic findings.
Specifications
| Viewing Head | Compensation-free trinocular, 30° inclined |
| Interpupillary Distance | 48 to 75 mm |
| Optical System | Color Corrected Infinity System () |
| Eyepieces | Pair of WF10X/22mm, high eyepoint, widefield |
| Diopter Adjustment | ±5 diopter on both eyepieces |
| Nosepiece | Reversed quintuple ball-bearing revolving nosepiece |
| Objectives | Infinite plan achromatic, anti-fungus treated |
| Objective 1 | 4x / NA 0.10 |
| Objective 2 | 10x / NA 0.25 |
| Objective 3 | 20x / NA 0.40 |
| Objective 4 | 40x / NA 0.65 (Spring-loaded) |
| Objective 5 | 100x / NA 1.25 (Spring-loaded, Oil) |
| Stage Type | Double layer mechanical stage |
| Stage Size | 180 mm x 160 mm |
| Stage Travel Range | 80 mm (X) x 50 mm (Y) |
| Stage Scales | Vernier scale on X and Y axes |
| Focusing System | Coaxial coarse & fine focusing |
| Fine Focus Accuracy | 2 μm |
| Fine Focus Stroke | 25 mm |
| Focusing Features | Upper limit stop, tension adjustment, anti-slip device |
| Condenser | Sliding-in, centerable Abbe condenser |
| Condenser NA | 1.25 |
| Illumination Type | 3W with Köhler illumination |
| Illumination Control | Brightness adjustable |
| C Mount | 0.5x C-Mount adapter |
| Digital Display | 9.7 |
| Camera Sensor | 1/2.5 |
| Pixel Size | 2.2 μm x 2.2 μm |
| Camera Resolution | 5 Megapixels (MP) |
| Image Resolution | 3840 x 2160 (4K ) |
| Video Support | 1080p Full HD |
| Operating System | Android 5.1 O.S. |
| Software | Built-in S- image software |
| Exposure Control | Automatic & Manual (0-999 ms) |
| White Balance | Auto, Manual, and Mode |
| Image Settings | Contrast, Saturation, Brightness, Sharpness, Noise Reduction |
| Connectivity | 2.0, , TF Card Slot, Wi-Fi, Bluetooth |
| Power Supply | Multi-plug 85-230Vac, 50/60Hz external adapter |
Features
Color corrected infinity system ()
Adjustable interpupillary distance
Double-layer mechanical stage
Stage travel range
Vernier scale on both x and y axes
Integrated coaxial coarse and fine focusing
3W lamp with köhler illumination
Integrated digital imaging system
1080p full HD video recording
Automatic and manual control of exposure
Target brightness setting
FAQs
1. What are the key factors to consider when selecting this microscope for laboratory use?
When selecting this microscope, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this microscope be calibrated to ensure accurate results?
It is recommended to calibrate this microscope at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this microscope?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this microscope be used with different types of samples, and are there any compatibility considerations?
Yes, this microscope can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the microscope malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

