Introduction
A sound level meter calibrator is a device used for the calibration of the sound level meters and the sound analyzers, by the generation of a known sound pressure level, and it is used in the occupational health, the environmental monitoring, the industry, the laboratories, and the many other applications. The sound level meter calibrator generates a stable sound pressure level, typically 94 decibels at 1000 hertz, with the internal speaker and the cavity, and it is placed over the microphone of the meter for the calibration, ensuring the accuracy of the measurements; the sound level meter calibrator consists of a sound generator, a cavity for the microphone, the electronics, and the controls, and it provides the known sound level, with features such as the automatic or the manual calibration; the sound level meter calibrator is used for the calibration of the sound level meters, for the verification of the sound analyzers, for the compliance with the standards, for the maintenance, and for many other applications, and it is an essential accessory for the noise measurement. Sound level meter calibrators are used in the occupational health, in the environmental monitoring, in the industry, in the laboratories, and for many other applications. With their known sound level, sound level meter calibrators are essential for the accurate noise measurement.
Wall Mount Sound Level Meter LSDM-T2011
Wall Mount Sound operates within a temperature range of -10°C to 50°C. It supports compliance with noise regulation and environmental standards. Its adjustable sensitivity ensures acc...
4-T6n-one Sound Level Meter LSDM-T2011
4-in-one Sound features a frequency range of 50 Hz to 8.5 kHz. It maintains accuracy across a broad decibel spectrum. Its robust internal components ensure long-term operational stabili...
Wall Mount Sound Level Meter LSDM-T2012
Wall Mount Sound has a humidity range of 20% to 85%, ideal for tracking moisture levels. It offers fast sampling rates for accurate detection of sudden noise changes. Its compact wall-m...
3-T6n-one Sound Level Meter LSDM-T2010
3-in-one Sound features an atmospheric pressure range of 12.5 to 15.4 . It provides real-time measurements of noise, temperature, and humidity. Its high-sensitivity microphone ensures a...
Wall Mount Sound Level Meter LSDM-T2010
Wall Mount Sound features a noise measuring range of 30 to 130 dBA. It monitors decibel levels, temperature, and humidity providing complete environmental analysis. Its multi-functional...
Sound Level Meter LSDM-T2011
Sound is a universal sound level meter that measures the exponential time weighted sound level. It is small in size, light in weight and easy to carry unit. It has 1/2 inch electret cond...
Sound Level Calibrator LSDC-T2010
Sound is a noise decibel calibration tool and used for quick and easy calibration of sound level meters and sound measuring systems. It offers frequency up to 1000 Hz and accuracy is 0.3...
Accurate Sound Level Meter LSDM-T2010
Accurate Sound is a universal sound level meter that measures the exponential time weighted sound level. It has Φ 12.7 mm (1/2) test condenser microphone and ranges from 25 dB to 130dB ...
Standards
IEC 61672-1:2013-Electroacoustics-Sound level meters-Specifications
ISO 16032:2024-Acoustics-Measurement of sound pressure level from service equipment or activities in buildings
ISO 16622:2002-Meteorology-Sonic anemometers/thermometers-Acceptance test methods for mean wind measurements
ISO/CIE 19476:2014-Characterization of the performance of illuminance meters and luminance meters
Complies with the above standards, but is not limited to them.
Features
1. Sound level meter calibrator for verifying and calibrating sound measurement instruments.
2. Produces precise reference sound pressure level at known frequency for accurate calibration.
3. Suitable for field and laboratory calibration of sound level meters and microphones.
4. Compact, portable design with battery operation for on-site calibration.
5. Includes calibrator, microphone adapter, calibration certificate and operation manual.
FAQ
Q1: What testing scenarios is this calibrator mainly applied to?
A: The sound level meter calibrator is used by acoustics professionals, occupational health and safety officers, environmental monitors and testing laboratories to verify and calibrate sound level meters, microphones and noise measurement instruments before and after measurements. It supports field calibration of sound level meters for environmental noise monitoring, occupational noise exposure assessment, industrial noise measurement and acoustics research. The calibrator produces a precise, stable reference sound pressure level at a known frequency, allowing users to verify that their measurement instrument is reading correctly and adjust if necessary. It is essential for any noise measurement program, as field calibration before and after each measurement session is required by standards such as IEC 61672 and occupational noise regulations to ensure measurement accuracy, data traceability and regulatory compliance for environmental and occupational noise assessments.
Q2: What standards does the calibrator comply with?
A: The calibrator complies with IEC 60942 for sound calibrators (Class 1 or Class 2), and relevant GB/T standards for acoustic calibration equipment. Calibration should be traceable to national standards through periodic laboratory calibration. The output sound pressure level and frequency should be verified by an accredited laboratory annually.
Q3: What is the warranty period for the whole machine and key components?
A: The whole calibrator is covered by a 12-month warranty. The electronics, transducer and housing are covered, while batteries and seals are consumables. Damage from dropping, moisture exposure or unauthorized repair is excluded. Extended service contracts are available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is simple: insert the microphone, activate the calibrator and verify the reading on the sound level meter. No professional training is required beyond basic familiarity with sound measurement equipment. We provide an operation manual and remote guidance. Proper microphone adapter selection and seal are important for accurate calibration.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: The calibrator itself should be calibrated by an accredited laboratory annually or per regulatory requirements to maintain traceability. Battery replacement when output level drops. Output level can be checked periodically against a reference. Routine inspection of the microphone adapter seal is recommended.
Q7: Are supporting consumables universal?
A: Batteries and microphone adapters are available from multiple suppliers, though adapter size should match the microphone diameter. Long-term consumable cost is very low.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes output sound pressure level, frequency, calibration class and adapter sizes. Additional adapters and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: No installation is required. The package includes the calibrator, adapters and instruction manual. On-site service is not included for this type of portable calibration equipment.
Q10: What types of instruments are compatible with this equipment?
A: The calibrator works with sound level meters and measurement microphones that fit the adapter size within the calibrator frequency and level range. Different microphone diameters require appropriate adapters. Users should ensure a proper seal between the microphone and calibrator, allow the calibrator to stabilize before reading, perform calibration at the measurement location temperature, and record calibration results before and after each measurement session for data traceability and regulatory compliance. The calibrator should be periodically sent to an accredited laboratory for calibration to maintain traceability.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.







