Introduction

A microplate centrifuge is a compact laboratory centrifuge designed to spin microplates, such as 96-well and 384-well plates, used for spinning down the contents of the wells, for removing bubbles from the wells, and for collecting samples and reagents at the bottom of the wells, and it is used in molecular biology, biochemistry, and clinical laboratories. The centrifuge consists of a rotor or platform that holds the microplate, a motor that spins the rotor, and controls for the speed and time; the microplate is placed in the centrifuge, and the rotor spins at a moderate speed, typically a few thousand revolutions per minute, generating a centrifugal force that moves the liquid in the wells to the bottom, removing air bubbles and ensuring that the samples and reagents are at the bottom of the wells for accurate pipetting and reading; the centrifuge is designed to hold standard microplate formats, and it provides a rapid and convenient spinning down of plates. Microplate centrifuges are used for spinning down PCR plates, for removing bubbles from wells before absorbance or fluorescence readings, for collecting samples at the bottom of wells before analysis, for mixing and settling the contents of wells, for cell pelleting in plates, for sample preparation for assays, and for many other applications, and they are available in various configurations, with features such as adjustable speed and time, a compact footprint, and low noise. With their convenience, microplate centrifuges are essential for preparing microplates for analysis.

Microplate Centrifuge LMPC-T2010

Microplate Centrifuge LMPC-T2010



Microplate Centrifuge features a compact design and operates within a speed range of 500 to 2500 rpm. It features an integrated -to- conversion function, offering enhanced versatility ac...
Microplate Centrifuge LMPC-T2011

Microplate Centrifuge LMPC-T2011



Microplate Centrifuge delivers a maximum speed of 2800 rpm for efficient sample separation in high-throughput laboratory applications. It offers touch or timer-based operation for greate...
Microplate Centrifuge LMPC-T2010

Microplate Centrifuge LMPC-T2010



Microplate Centrifuge comes with a speed range of 500 rpm to 2000 rpm. It has a special ventilation design with the temperature protection function in matching cavity. Additionally, it h...
Microplate Centrifuge LMPC-T2010

Microplate Centrifuge LMPC-T2010



Microplate Centrifuge boasts a maximum speed of 2800 rpm, ensuring rapid sample processing. It generates a powerful centrifugal force of up to 600 × g, making it ideal for a variety of ...
Microplate Centrifuge LMPC-T2011

Microplate Centrifuge LMPC-T2011



Microplate Centrifuge has a maximum capacity of 2 × 96-well plates and a maximum of 608 × g for efficient sample processing. It features an for easy monitoring of results and error ide...
Microplate Centrifuge LMPC-T2010

Microplate Centrifuge LMPC-T2010



Microplate Centrifuge operates at 2200 to 2800 rpm, providing accurate control for consistent sample processing. Its wide plate compatibility supports skirted, non-skirted, and semi-skir...

Standards

IEC 61010-2-020:2016-Particular requirements for laboratory centrifuges

Complies with the above standards, but is not limited to them.

Features

1. Microplate centrifuge for rapid spinning down of samples in microplates.

2. Compact design for quick spin-down of 96-well and 384-well plates.

3. Suitable for molecular biology, clinical, pharmaceutical, food and research labs.

4. Includes plate rotor, chamber, lid, controller, safety interlock and manual.

5. Supports quick spin-down for PCR, ELISA, cell culture and assay setup.

FAQ

Q1: What testing scenarios is this centrifuge mainly applied to?

A: The microplate centrifuge is used in molecular biology, clinical diagnostics, pharmaceutical research, food testing, biotechnology and research to rapidly spin down samples in microplates (96-well, 384-well, PCR plates) for assay setup, reagent collection and sample preparation. It supports PCR plate spin-down before thermal cycling, ELISA reagent collection, cell culture plate centrifugation, assay setup for high-throughput screening, and general microplate sample preparation. The compact design provides quick, convenient spin-down to collect droplets from plate walls and lids, ensuring all sample is at the well bottom for accurate assays.

Q2: What standards does the centrifuge comply with?

A: The microplate centrifuge complies with relevant IEC 61010 laboratory electrical safety standards, IEC 61326 for electromagnetic compatibility, and applicable GB/T standards for centrifuges. The rotor should be certified for the maximum speed and load. The instrument follows applicable safety standards including lid interlock. Users should verify compliance with specific facility requirements.

Q3: What is the warranty period for the whole machine and key components?

A: The whole microplate centrifuge is covered by a 12-month warranty. The motor, rotor, controller, chamber and housing are covered, while plate adapters, mats and fuses are accessories or consumables. Damage from improper use, overloading or unauthorized repair is excluded. Extended service contracts may be available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation is simple: place the microplate in the rotor, close the lid, set time/speed (or use pulse), and start. No professional training is required, but users should follow proper plate loading, balancing and safety procedures. We provide an operation manual and remote guidance.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular maintenance required? What is the recommended maintenance cycle?

A: Speed calibration recommended annually for critical applications. Rotor inspection for wear and cracks periodically. Routine cleaning of chamber and rotor. Lid interlock verified. Full system performance check annually. Motor and drive checked per manufacturer schedule.

Q7: Are supporting consumables universal?

A: Plate adapters, mats and fuses are available from laboratory suppliers, though compatibility should be verified. Long-term consumable cost is very low for a microplate centrifuge.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes maximum speed, plate capacity (single, dual), rotor type, control features (pulse, timer), and accessories. Additional plate adapters can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: No installation is required. The package includes the microplate centrifuge and instruction manual. On-site service is not included for this type of laboratory equipment.

Q10: What types of plates are compatible with this equipment?

A: The microplate centrifuge spins standard 96-well, 384-well and PCR plates within the plate size, speed range and rotor specification. Different plate types may require specific adapters or mats. Plates should be properly sealed to prevent spillage during centrifugation. When spinning two plates, they should be balanced (opposite positions). Users should ensure plates are properly seated in the rotor, use appropriate adapters for different plate types, balance loads when using dual rotors, set appropriate speed and time for the application, follow proper biosafety procedures for infectious samples, and not exceed the maximum speed rating. The centrifuge should be placed on a stable, level surface. The chamber should be cleaned regularly, especially after sample spills. The rotor should be inspected for cracks and wear. The lid safety interlock should never be bypassed. For PCR applications, the spin-down should be performed before thermal cycling to ensure all reagents are collected at the well bottom. The centrifuge should not be used for high-speed or long-duration separations; it is designed for quick spin-down only. Plates should be properly sealed with caps, mats or film to prevent cross-contamination and aerosolization.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry