Introduction
Microplate Reader analyzes large sample volumes with a wavelength range of 400 nm to 850 nm. These offer versatile detection modes, including absorbance, fluorescence, and luminescence. They include automated data collection for streamlined analysis. These readers include built-in software for easy data analysis and visualization. They provide precise temperature control for enhanced accuracy. Our Microplate Reader delivers consistent performance in active laboratory settings.
Microplate Reader T-MR-S2300
Microplate Reader T-MR-S2201
Microplate Reader T-MR-S2200
Microplate Reader T-MR-S2103
Microplate Reader T-MR-S2102
Microplate Reader T-MR-S2101
Microplate Reader T-MR-S2100
Microplate Reader T-MR-M1040
Microplate Reader T-RW-S2102
Microplate Reader T-RW-S2101
Microplate Reader T-RW-S2100
Microplate Reader T-MR-M1030
Microplate Reader T-MR-M1020
ELISA Microplate Reader T-MR-M1010
ELISA Microplate Reader T-ER-L6010
Microplate Reader T-S214MPR
Microplate Reader within a wavelength range of 400 nm to 800 nm, making it ideal for various absorbance-based assays. It features a wide reading range from 0.000 to 4.000 A, ensuring pre...
Microplate Reader T-S213MPR
Microplate Reader a broad wavelength range of 400 to 800 nm, enabling versatile applications across various assays. It measures absorbance from 0.000 to 4.000 A, delivering high precision...
Microplate Reader T-S212MPR
Microplate Reader a broad 400 nm to 800 nm wavelength range, ensuring versatile compatibility with various colorimetric assays. It measures absorbance from 0.000 to 4.000 A, ensuring accu...
Microplate Reader T-S211MPR
Microplate Reader a broad readout range from 0.000 to 3.500 Abs, ensuring accurate detection across low to high absorbance levels. It supports multiple key wavelengths 405, 450, 492, and ...
Multi-Mode Microplate Reader T-S210MMM
Multi-Mode Microplate Reader features absorbance, fluorescence, and luminescence detection mode. Features PID temperature control technology and 10-inch touch screen interface with LCD co...
Microplate Reader T-S210MPR
Microplate reader is a semi-automatic benchtop photometric unit for sample analysis in Microtiter plates. It is characterized with silicon photodiodes detector as a detection unit of biol...
ELISA Microplate Reader MR2065
ELISA Microplate Reader is a monochromator-based UV-Visible microplate spectrophotometer covering the full 200–1000 nm wavelength range for high-precision absorbance analysis. It support...
Elisa Microplate Reader MR2064
Elisa Microplate Reader supports both 96 and 48 well plates, enabling multiple tests on a single platform. It is equipped with a silicon photodiode photodetector for precise optical measu...
Elisa Microplate Reader MR2063
Elisa Microplate Reader is a compact and dependable reader that provides accurate and fast photometric measurements via bi-chromatic 8 channel optic fiber scanning, making it designed for...
Elisa Microplate Reader MR2061
Elisa Microplate Reader is a simple and dependable reader that provides accurate and quick photometric measurements via eight channel optic fiber scanning. It is designed for assays with ...
Elisa Microplate Reader MR2062
Elisa Microplate Reader is a basic reader that can also be used to quantify a variety of other colorimetric assays. By performing 12 different tests in one plate, this device can measure ...
Standards
IEC 61010-2-101:2018-Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-081:2015-Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes
Complies with the above standards, but is not limited to them.
Features
1. Reagent and sample probes with wash stations reduce carryover.
2. On-board quality control and flags support result confidence.
3. Clear software displays results, flags and status.
4. Data interfaces connect to laboratory information systems.
5. Compact or high-throughput models suit different workloads.
FAQ
What is the Microplate Reader mainly used for?
The Microplate Reader is used in clinical laboratories to measure patient samples for diagnostic and monitoring results. It supports hospitals, clinics and reference laboratories handling chemistry, haematology, immunoassay or related tests.
What standards does the Microplate Reader comply with?
The analyzer is designed with reference to applicable medical-device and in-vitro diagnostic standards, IEC electrical-safety requirements and relevant GB/T standards. Methods should follow validated diagnostic procedures. Compliance documentation can be provided on request.
What does the warranty cover?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
How easy is the Microplate Reader to use?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
How often should the Microplate Reader be calibrated?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Are the consumables universal or proprietary?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can the Microplate Reader be customised?
Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.
How is the Microplate Reader commissioned?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not use expired reagents, skip quality control or operate without trained staff. Follow sample handling, calibration and maintenance schedules. Follow laboratory quality rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.


























