Introduction

A UV-VIS spectrometer measures ultraviolet and visible light absorption. It is widely used in laboratories. The system ensures quantitative analysis. It solves manual optical measurement errors. By providing broad-spectrum detection, it supports chemical and biological research.

UV-VIS Spectrometer LUVI-T2011

UV-VIS Spectrometer LUVI-T2011



UV- Spectrometer offers a wavelength range of 240 to 900 nm, catering to measurements from ultraviolet to visible light. It is equipped with advanced a high-resolution linear detector an...
UV-VIS Spectrometer LUVI-T2010

UV-VIS Spectrometer LUVI-T2010



UV- Spectrometer offers a compact design that offers a wavelength range of 200 to 755nm. It features a fixed optical grating that maintains consistent signal stability during long-term u...

Standards

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

USP General Chapter <857>-Ultraviolet-Visible Spectroscopy

Complies with the above standards, but is not limited to them.

Features

1. Multiple modes support absorbance, transmittance, concentration and kinetics.

2. Automatic wavelength calibration and self-checks support reliability.

3. Software tools support spectral scans, standard curves and kinetics.

4. Long-life lamp reduces routine replacement and downtime.

5. Diffraction grating or monochromator provides precise wavelength selection.

FAQ

What is the UV-VIS Spectrometer mainly used for?

The UV-VIS Spectrometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

What standards does the UV-VIS Spectrometer comply with?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

How long is the warranty period?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Will staff need special training?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.

Where do we get replacement parts?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Can it be adapted to our requirements?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.

What should be avoided when using the UV-VIS Spectrometer?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.