Introduction

Split Beam UV-Vis Spectrophotometer offers a wide wavelength range of 190 to 1100 nm. They include an automatic setting for easy handling. These divide light into two paths, allowing simultaneous measurement of reference and sample. Their 7-inch multi-color touchscreen improves operational efficiency. Split Beam UV-Vis Spectrophotometer is suitable for biological and chemical analysis, including DNA, protein quantification, water, and solvent testing.

暂无信息

Standards

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

USP General Chapter <857>-Ultraviolet-Visible Spectroscopy

Complies with the above standards, but is not limited to them.

Features

1. Clear digital or software interface simplifies measurement and data handling.

2. Software tools support spectral scans, standard curves and kinetics.

3. USB, RS232 or printer options export results and reports.

4. Long-life lamp reduces routine replacement and downtime.

5. Wide wavelength range covers common analytical applications.

FAQ

What is the Split Beam UV-Vis Spectrophotometer mainly used for?

The Split Beam UV-Vis Spectrophotometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

Which standards and regulations apply to the Split Beam UV-Vis Spectrophotometer?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

How long is the warranty period?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

How easy is the Split Beam UV-Vis Spectrophotometer to use?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Split Beam UV-Vis Spectrophotometer need calibration or verification?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Where do we get replacement parts?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can it be adapted to our requirements?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

How is the Split Beam UV-Vis Spectrophotometer commissioned?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What maintenance and safety points matter?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.