Introduction
Biosafety Cabinet (Class ll A2) provides optimal airflow, with an inflow of 490 m³/h and downflow of 910 m³/h, ensuring a secure environment. Its two filters deliver 99.9995% filtration efficiency for particles as small as 0.12 µm. The power-off memory function restores settings after a power loss, offering added convenience. The ergonomic design includes a 10° inclined viewing angle, improving user comfort and visibility. Designed for handling biological materials, it guarantees safety and sterility in laboratory environments.
This biosafety cabinet is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Biosafety Cabinet Class II A2 is used in research labs, pharmaceuticals, and healthcare settings. It ensures safe handling of infectious agents, cell cultures, and biological materials, providing optimal safety and contamination control.
Specifications
| Work Surface Height | 750 mm |
| Max Opening | 500 mm |
| Tested Opening | 200 mm |
| Airflow Volume | Inflow: 490 m³/h (289 cfm) Downflow: 65%: 910 m³/h (536 cfm) Exhaust: 35%: 490 m³/h (289 cfm) |
| Front Window | Manual and electric, glass thickness> 5mm, anti-ultraviolet |
| Filter | 2 pcs, filtration efficiency for 0.12 µm particles ≥ 99.9995% |
| Illumination | ≥1000 Lux |
| Noise | ≤ 65 dB |
| Display | Color Touch Screen |
| European Standard Socket | 230 V, 3 A |
| Alarm system | Abnormal wind speed, Glass door safety, Power failure |
| Motor | AC single fan, Adjustable speed, Energy-efficient |
| Material | Working Area: 304 stainless steel, Frame: Cold-rolled steel with antibacterial coating |
| Lamp | 14 W × 2 |
| UV Lamp | 30 W |
| Power Supply | AC 230 V, 50 Hz |
| Power Consumption | 1200 W |
| Interior dimension (W × D × H) | 1280 × 600 × 650 mm |
| Exterior dimension (W × D × H) | 1383 × 800 × 2260 mm |
| Packaging Dimension (W × D × H) | 1530 × 1060 × 1880 mm |
| Gross Weight | 345 Kg |
Features
7-Inch Color Touch Display
Automatic Wind Speed Adjustment
Power-on Password Protection
Interlocking UV and Fan Control
Ergonomic Height-Adjustable Base
Real-time Breeze Speed Monitoring
Easy Disassembly for Cleaning
Anti-Dust Paper Structure
One-Button Front Window Function
Side Windows for Observation
FAQs
1. What are the key factors to consider when selecting this biosafety cabinet for laboratory use?
When selecting this biosafety cabinet, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this biosafety cabinet be calibrated to ensure accurate results?
It is recommended to calibrate this biosafety cabinet at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this biosafety cabinet?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this biosafety cabinet be used with different types of samples, and are there any compatibility considerations?
Yes, this biosafety cabinet can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the biosafety cabinet malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

