Introduction
A nucleic acid purification system extracts DNA and RNA from biological samples. It is widely used in molecular biology and clinical diagnostics. It solves time-consuming manual extraction and ensures high purity and consistent yield for genetic analysis.
Nucleic acid purification system LNAP-T2011
Nucleic acid purification system is a benchtop unit for and purification with automated low throughput sample preparation Capable of extracting 1 to 20 samples per run with a working vol...
Nucleic acid purification system LNAP-T2012
Nucleic acid purification system is a benchtop unit for and purification with automated low throughput sample preparation Capable of extracting 1 to 32 samples per run with a working vol...
Nucleic acid purification system LNAP-T2010
Nucleic acid purification system is a benchtop unit for and purification with automated low throughput sample preparation Capable of extracting 1 to 20 samples per run with a working vol...
Nucleic Acid Purification System LNAP-T2050
Nucleic Acid Purification System is a benchtop unit comes with sample quantity of 96 and process volume of 50 to 1000 µl, offers lysis temperature ranges from ambient temperature to 120...
Nucleic Acid Purification System LNAP-T2040
Nucleic Acid Purification System adopts magnetic bead separation technology with consumable of 10 ml tube strips and magnetic rod’s tip. It is a benchtop unit comes with sample quantity...
Nucleic Acid Purification System LNAP-T2021
Nucleic Acid Purification System adopts magnetic bead separation technology with consumable of 5 ml tube strip and magnetic rod’s tip. Integrated with program management includes PC sof...
Nucleic Acid Purification System LNAP-T2030
Nucleic Acid Purification System is a benchtop unit comes with sample quantity of 16 and process volume ranges from 50 to 1000 µl. Offers elution temperature ranges from ambient tempera...
Nucleic Acid Purification System LNAP-T2020
Nucleic Acid Purification System is a benchtop unit comes with sample quantity of 10 and process volume ranges from 50 to 1000 µl. Adopted with magnetic bead separation technology with ...
Standards
ISO 17822:2020-In vitro diagnostic test systems-Nucleic acid amplification-based examination procedures-Laboratory quality practice guide
Complies with the above standards, but is not limited to them.
Features
1. Data export and analysis support research records.
2. Fast block ramps shorten overall protocol time.
3. Clear display or software shows run status and data.
4. Compact bench design fits molecular laboratories.
5. Precise thermal or optical control supports accurate results.
FAQ
What are the main applications of the Nucleic Acid Purification System?
The Nucleic Acid Purification System is used in molecular and cell biology for amplification, separation, imaging or sample preparation. It supports PCR, electrophoresis, nucleic-acid work and related research and diagnostic laboratories.
What standards does the Nucleic Acid Purification System comply with?
The instrument is designed with reference to IEC 61010 electrical safety, applicable molecular-biology methods and relevant GB/T standards. Programs and reagents should follow validated protocols. Compliance documentation can be provided on request.
What does the warranty cover?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
Will staff need special training?
Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Nucleic Acid Purification System need calibration or verification?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Are the consumables universal or proprietary?
The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.
Can it be adapted to our requirements?
A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.
Do you provide on-site installation?
Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.
What maintenance and safety points matter?
Do not use contaminated samples or reagents, skip controls or block thermal or optical paths. Prevent cross-contamination and maintain calibration. Follow laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.








