Introduction
Automatic nucleic acid extraction system streamlines nucleic acid purification from diverse sample sources, utilizing a magnetic beads extraction system. It integrates a shaking and heating module station with a concave design heating belt, accommodating deep hole tubes and reducing extraction time. The compact design includes a HEPA filter and UV sterilization lamp, ensuring a highly efficient sterilized environment. The system features an LCD touchscreen display with a Windows operating system, offering a user-friendly interface for an optimal user experience, making it a comprehensive solution for precise and efficient nucleic acid isolation in various laboratory settings.
Nucleic Acid Extractor T-NAE-L2100
Nucleic Acid Extractor T-NAE-S2107
Nucleic Acid Extractor T-NAE-S2108
Nucleic Acid Extractor T-NAE-S2103
Nucleic Acid Extractor T-NAE-S2104
Nucleic Acid Extractor T-NAE-S2105
Nucleic Acid Extractor T-NAE-S2102
Automatic Nucleic Acid Extraction System T-NAE-S2101
Automatic Nucleic Acid Extraction System T-NAE-S2100
Automatic Nucleic Acid Extraction System T-S210NAE
Automatic Nucleic Acid Extraction System facilitates purification and isolation of nucleic acid from variety of sample sources and volumes using magnetic beads extraction system. Features...
Standards
ISO 17822:2020-In vitro diagnostic test systems-Nucleic acid amplification-based examination procedures-Laboratory quality practice guide
Complies with the above standards, but is not limited to them.
Features
1. Multiple channels or samples support throughput.
2. Compact bench design fits molecular laboratories.
3. Program libraries and user management support shared laboratory use.
4. Programmable protocols store cycling or imaging steps.
5. Fast block ramps shorten overall protocol time.
FAQ
What is the Automatic Nucleic Acid Extraction System mainly used for?
The Automatic Nucleic Acid Extraction System is used in molecular and cell biology for amplification, separation, imaging or sample preparation. It supports PCR, electrophoresis, nucleic-acid work and related research and diagnostic laboratories.
What standards does the Automatic Nucleic Acid Extraction System comply with?
The instrument is designed with reference to IEC 61010 electrical safety, applicable molecular-biology methods and relevant GB/T standards. Programs and reagents should follow validated protocols. Compliance documentation can be provided on request.
What does the warranty cover?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
How easy is the Automatic Nucleic Acid Extraction System to use?
Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Automatic Nucleic Acid Extraction System need calibration or verification?
To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.
Where do we get replacement parts?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can the Automatic Nucleic Acid Extraction System be customised?
Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.
How is the Automatic Nucleic Acid Extraction System commissioned?
Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.
What maintenance and safety points matter?
Do not use contaminated samples or reagents, skip controls or block thermal or optical paths. Prevent cross-contamination and maintain calibration. Follow laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.