Introduction
PCR Cabinet offers 51-inch workspace ensures spacious arrangement, supporting seamless activity in controlled surroundings. Equipped with a High Efficiency Particulate Air (HEPA) filtration with 99.999% efficiency at 0.3 µm for superior air purification. Integrated with a 5 mm thick motorized front and side panel, ensuring smooth functionality. Incorporated with an LED lighting system delivering 1000 Lux brightness for enhanced visibility. PCR Cabinet is built for durability, ensuring reliable performance across extended operational periods.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
PCR Cabinet is vital for gene cloning, sequencing and protein analysis in biotechnology research under sterile conditions.
Selection Guide
PCR Cabinet is designed to provide a clean and controlled environment for sensitive molecular biology applications such as DNA amplification, PCR sample preparation, and contamination-free experiments. Based on a research study, this cabinet is suitable for laboratories that prioritize sample integrity and operator safety. With a cabinet size of 51 inches, it provides a wider workspace, accommodating multiple samples or larger experimental setups. The airflow velocity of 0.3 to 0.5 m/s and an exhaust volume of 580 to 970 m³/h ensure consistent air circulation and effective removal of contaminants. The maximum door opening height of 300 mm facilitates easy access while maintaining barrier protection. Customers should also consider certifications such as CE or ISO, which indicate compliance with international safety and quality standards. This model is well-suited for research institutions, clinical diagnostics, and pharmaceutical labs requiring reliable contamination control during PCR procedures.
Specifications
| Cabinet Size | 51 Inches |
| Airflow Velocity | 0.3 to 0.5 m/s |
| Exhaust Volume | 580 to 970 m³/h |
| Maximum Door Opening Height | 300 mm |
| Working Surface Height | 750 mm |
| Glass Door Thickness | Motorized, 5 mm thick (Front and Side) |
| Pre-Filter | Polyester fiber |
| HEPA Filter | 99.999 % efficiency at 0.3 µm |
| Cleanliness Class | Class 100 |
| UV Lamp | 30 W |
| Illuminating Lamp | 12 W LED Lamp |
| Illumination | Greater than or equal to 1000 Lux |
| Display | LCD Display |
| Noise | Less than 65 dB |
| Product safety | Less than or equal to 0.5 CFU / time |
| Power Consumption | 600 W |
| Power Supply | AC 220 / 110 V ± 10 % ; 50 / 60 Hz |
| Internal Dimension | 1200 × 595 × 550 mm |
| External Dimension | 1300 × 700 × 1770 mm |
| Gross Weight | 180 kg |
Features
Polyester Fiber Pre-Filter
Digital LCD Display
Energy Efficient Power Consumption
Maximum Door Opening Height
Low Vibration Mechanism
Standard Accessories
FAQs
1. What is the main function of this Laboratory Instrument?
It is a professional laboratory instrument designed for Laboratory Instrument applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Laboratory Instrument compared to similar products?
It incorporates advanced technologies including HEPA filtration, ensuring superior performance in terms of stability, accuracy, and operational convenience. The durable construction and strict quality control also guarantee long service life and low maintenance costs.
3. What regular maintenance is required for this Laboratory Instrument?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Laboratory Instrument?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Laboratory Instrument shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.