Introduction

An acid and alkali tester is an instrument used to measure the acidity and the alkalinity of the solutions, which is expressed by the pH value, and it is used in the laboratories, the water treatment, the environmental monitoring, the agriculture, and the many other applications. The acid and alkali tester measures the pH by the measurement of the potential difference between the pH electrode and the reference electrode, and it provides the pH value, with the temperature compensation; the acid and alkali tester consists of a meter with the display, a pH electrode, a temperature sensor, and the controls, and it provides features such as the calibration and the automatic temperature compensation; the acid and alkali tester is used for the measurement of the pH of the water, the wastewater, the soil, the foods, the cosmetics, and the other solutions, for the quality control, for the monitoring, for the agriculture, for the education, and for many other applications, and it is available as the benchtop, the portable, and the pen type instruments; the acid and alkali tester is an essential instrument for the pH measurement. Acid and alkali testers are used in the laboratories, in the water treatment, in the environmental monitoring, in the agriculture, and for many other applications. With their pH measurement, acid and alkali testers are essential for the acidity and the alkalinity assessment.

Oil Acidity Tester LAAT-T2016

Oil Acidity Tester LAAT-T2016



Oil Acidity Tester supports testing range from 0.0001 to 5.0000mg /g. Automates liquid transfer, stirring, endpoint judgment, and result storage for simplified operation. Automatically a...
Water-soluble Acidity Tester LAAT-T2015

Water-soluble Acidity Tester LAAT-T2015



Water-soluble Acidity Tester provides a measuring range of 0.001 to 1mg /g. Offers batch processing of up to 3 samples per run. Streamlines the testing process with automated sample inje...
Base Number Tester LAAT-T2014

Base Number Tester LAAT-T2014



Base Number Tester utilizes potentiometric titration to automatically identify the base number at ≥ 0.001 mg /g. It has a burette capacity of 10 ml with a minimum of 0.001 ml titration ...
Base Number Tester LAAT-T2013

Base Number Tester LAAT-T2013



It is composed of automatic potential titrator and titration device. It is designed according to Industry Standard of Petrochemical and follows D2896 and D4739 “Test Methods for Base Nu...
Acid Number and Acidity Tester LAAT-T2011

Acid Number and Acidity Tester LAAT-T2011



It is designed as per a “Test Methods for Acid Number of Petroleum Products” and “Test Methods for Acidity of Gasoline, Kerosene, and Diesel oil”. This petroleum testing is designed ...
Acid Number Tester LAAT-T2012

Acid Number Tester LAAT-T2012



Acid Number Tester is automated and controlled by microprocessor unit. It offers 0 to 1800.0 mV potential measurement range and ≥0.05 mg /g acid number measurement range. It works on po...
Water Soluble Acid and Alkali Tester LAAT-T2010

Water Soluble Acid and Alkali Tester LAAT-T2010



It is deliberately fabricated to have high accuracy and easy operation mode. It is constructed as per “Test Methods for Water Soluble Acid and Alkali of Petroleum Products”. This petro...

Standards

IEC 60746-1:2003-Expression of performance of electrochemical analyzers-Part 1: General

Complies with the above standards, but is not limited to them.

Features

1. Acid and alkali tester for measuring acidity and alkalinity of solutions and products.

2. Precision pH measurement with automatic temperature compensation for accurate results.

3. Suitable for chemical, food, pharmaceutical, water treatment and quality control applications.

4. Includes pH electrode, temperature sensor, calibration solutions and meter.

5. Supports both laboratory and field measurement of acid-base properties.

FAQ

Q1: What testing scenarios is this tester mainly applied to?

A: The acid and alkali tester is used in chemical manufacturing, food and beverage production, pharmaceutical quality control, water treatment, environmental monitoring and agricultural testing to measure the acidity or alkalinity of solutions, products and samples. It supports pH measurement for chemical process control, food and beverage quality assessment, pharmaceutical formulation testing, water and wastewater treatment monitoring, soil and agricultural analysis, and environmental water quality assessment. The tester provides a direct indication of acid-base balance, which is critical for product quality, process optimization, corrosion control and regulatory compliance. It is essential for laboratories and production facilities requiring reliable pH measurement for quality control, process monitoring, environmental compliance and product development, where acid-base properties affect chemical reactions, product stability, taste, safety and environmental impact across multiple industries.

Q2: What standards does the tester comply with?

A: The pH meter complies with ISO 10523 for water quality pH determination, relevant GB/T standards, and IEC 61010 laboratory safety standards. Calibration should use certified pH buffer solutions traceable to international standards. Food and pharmaceutical applications follow applicable pharmacopoeial and industry standards.

Q3: What is the warranty period for the whole machine and key components?

A: The whole tester is covered by a 12-month warranty. The meter unit and electrode are covered, while calibration solutions and batteries are consumables excluded from warranty. Electrode damage from improper storage, drying or corrosive samples is also excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires basic training in pH measurement, electrode calibration and maintenance. We provide an operation manual and remote guidance. Proper electrode calibration, storage and sample handling are important for accurate pH results.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Calibration with certified pH buffers should be performed before each use session for critical measurements. Full meter calibration recommended every 6-12 months. Electrode condition monitored and cleaning or regeneration performed when readings become sluggish. Storage solution level maintained for refillable electrodes.

Q7: Are supporting consumables universal?

A: Calibration buffers, storage solutions and electrode filling solutions are available from chemical suppliers, though certified standards are recommended for accuracy. Electrodes may be model-specific and should be sourced from the manufacturer or authorized distributor.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes measurement range, electrode type, temperature compensation and data output. Additional electrodes, probes and calibration solutions can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: No complex installation is required beyond electrode connection and power. The package includes the meter, electrode, calibration solutions and instruction manual. On-site calibration and training service are available at additional cost.

Q10: What types of samples are compatible with this equipment?

A: The tester measures pH of aqueous solutions within the measurement range and temperature specification. Highly corrosive samples may damage electrodes and require special material selection. Very low ionic strength samples require special electrodes and techniques. Non-aqueous samples require appropriate electrodes and calibration. Users should select appropriate electrodes for the sample matrix, follow proper calibration and storage procedures, ensure adequate electrode response time, and clean electrodes between measurements to prevent cross-contamination and maintain accuracy.