Introduction

Benchtop Incubator Shaker operates with temperature control and uniform shaking motion. They feature intuitive interface for effortless parameter settings, monitoring, and real-time adjustments. These are equipped with safety alarms and protection systems for uninterrupted, secure operation. Their durable construction ensures long-term reliability and resistance. Benchtop Incubator Shaker is suitable for research, pharmaceutical, and industrial settings.

Benchtop Incubator Shaker T-L2IS-S2300

Benchtop Incubator Shaker T-L2IS-S2300

Benchtop Incubator Shaker supports 5 kg load capacity and operates from 50 to 300 rpm. Designed with uniform shaking action and consistent thermal regulation. Equipped with spacious platfo...
Benchtop Incubator Shaker T-L2IS-S2301

Benchtop Incubator Shaker T-L2IS-S2301

Benchtop Incubator Shaker offers 10 kg capacity with speed range of 50 to 300 rpm. Designed with enhanced platform size to accommodate larger vessels and containers. Incorporated with effi...
Benchtop Incubator Shaker T-L2IS-L2100

Benchtop Incubator Shaker T-L2IS-L2100

Benchtop Incubator Shaker speed from 10 to 400 rpm. It operates from 4℃ to 65℃, suitable for both refrigerated and heated incubation. It is equipped with intuitive LCD touch screen for e...
Benchtop Incubator Shaker T-L2IS-S2200

Benchtop Incubator Shaker T-L2IS-S2200

Benchtop Incubator Shaker operates at temperature range of 4 to 60 °C. Its BRIGHT I system with touchscreen and dual timing ensures control of parameters, modes, and segments. Its lock sc...
Benchtop Incubator Shaker T-L2IS-S2201

Benchtop Incubator Shaker T-L2IS-S2201

Benchtop Incubator Shaker offers temperature range of 4 to 60 °C. Its BRIGHT I system offers touchscreen control and dual timers for managing modes and program segments. Its brushless DC ...
Benchtop Incubator Shaker T-L2IS-S2103

Benchtop Incubator Shaker T-L2IS-S2103

Benchtop Incubator Shaker works between room temperature and 60 °C. Its PMMA II system with dual parameter display enables convenient monitoring and efficient operation. Its adjustable os...
Benchtop Incubator Shaker T-L2IS-S2102

Benchtop Incubator Shaker T-L2IS-S2102

Benchtop Incubator Shaker provides volume of 45 litres. Its single axis drive with adjustable oscillation amplitude enables customizable linear shaking motion. Its operating parameters inc...
Benchtop Incubator Shaker T-L2IS-S2100

Benchtop Incubator Shaker T-L2IS-S2100

Benchtop Incubator Shaker offers rotation rate of 30 to 300 rpm. It features single axis drive with infinitely adjustable oscillation amplitude for customizable linear shaking. Its PMMA II...
Benchtop Incubator Shaker T-L2IS-S2101

Benchtop Incubator Shaker T-L2IS-S2101

Benchtop Incubator Shaker offers volume of 70 litres. Its operating parameters include encryption and memory functions to prevent data loss and unauthorized changes. It features PMMA II co...

Standards

ISO/TS 23565:2021-Biotechnology-Bioprocessing-General requirements and considerations for equipment used in the manufacturing of cells for therapeutic uses

Complies with the above standards, but is not limited to them.

Features

1. Digital display shows speed, time and temperature clearly.

2. Smooth chamber and removable platform simplify cleaning.

3. Timer and continuous modes support unattended operation.

4. Slow-start and imbalance protection reduce spills.

5. Combined temperature control and orbital shaking in one compact unit.

FAQ

What are the main applications of the Benchtop Incubator Shaker?

The Benchtop Incubator Shaker combines controlled incubation with orbital shaking, supporting cell culture, microbiology, solubility and expression work that needs both temperature control and aeration. It is used in biotechnology, pharmaceutical and research laboratories.

What standards does the Benchtop Incubator Shaker comply with?

The unit is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for incubators and laboratory mixing equipment. Compliance documentation can be provided on request.

What does the warranty cover?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

How easy is the Benchtop Incubator Shaker to use?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Where do we get replacement parts?

Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.

Can the Benchtop Incubator Shaker be customised?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What maintenance and safety points matter?

Do not run flammable or highly volatile media or overload the platform beyond the rated load. Secure flasks properly and balance the load. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry