Introduction

Bench Top Steam Sterilizer offers an extensive range of capacities for diverse needs and applications. Their user-friendly interface allows for effortless control of time, temperature, and cycle settings. They are designed with safety protocols such as automatic shut-off, pressure control, and door locks. They are built with high-quality materials to withstand frequent use. Our Bench Top Steam Sterilizer ensures the safety and cleanliness of instruments.

Bench Top Steam Sterilizer BS2054

Bench Top Steam Sterilizer BS2054


Bench Top Steam Sterilizer is designed to provide high performance with a 50L chamber volume. It operates at a temperature of 134℃ and 0.22MPa pressure for efficient sterilization. Integ...
Bench Top Steam Sterilizer BS2053

Bench Top Steam Sterilizer BS2053


Bench Top Steam Sterilizer is a front-loading sterilizer with 35L chamber capacity. It is operated at 134℃ under 0.22MPa pressure for effective sterilization. Built-in timer cycle range ...
Bench Top Steam Sterilizer BS2052

Bench Top Steam Sterilizer BS2052


Bench Top Steam Sterilizer is a heavy-duty, front-loading sterilizer with an 18L capacity. It is equipped with a larger chamber opening that allows easy loading and unloading of samples. ...
Bench Top Steam Sterilizer BS2051

Bench Top Steam Sterilizer BS2051


Bench Top Steam Sterilizer is a high-performance front-loading sterilizer with a 24L capacity. It incorporates flexibility and ease of operation, ensuring reliable laboratory applications...

Standards

IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Complies with the above standards, but is not limited to them.

Features

1. Digital display shows temperature, pressure and cycle stage.

2. Vertical, horizontal and benchtop models suit various spaces.

3. Automatic air removal and drying improve sterilization results.

4. Printer or data-logger option provides cycle records.

5. Over-pressure, over-temperature and low-water protection included.

FAQ

What is the Bench Top Steam Sterilizer mainly used for?

The Bench Top Steam Sterilizer is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.

What standards does the Bench Top Steam Sterilizer comply with?

The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.

What warranty comes with the Bench Top Steam Sterilizer?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Is the Bench Top Steam Sterilizer difficult to operate?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Bench Top Steam Sterilizer be calibrated?

To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.

Where do we get replacement parts?

Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.

Can it be adapted to our requirements?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Is installation and commissioning included?

Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.

What maintenance and safety points matter?

Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.