Introduction

Low Speed Centrifuge operates at speed ranging of 300 to 4500rpm, ensuring precise and efficient separation. Equipped with multiple rotor options for accommodating various tube sizes and sample volumes. Its intuitive programming modes simplify operation for users of all experience levels. Offers low heat emission to ensure integrity and prevents unwanted thermal effects. Integrate balancing mechanism making it ideal for handling infectious and hazardous biological samples.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Our Low Speed Centrifuge is ideal for separation of whole blood components, such as serum, plasma, buffy coat, red blood cells, as well as other bodily fluids and provides sample separation, ideal for clinical, medical, and research applications, ensuring smooth operation, high performance, and safety with customizable speed settings.

Specifications

Speed Range 300 to 4500 rpm in 10 rpm increment
Max. 2490×g
Speed Accuracy ±20 rpm
Rotor Type Plastic Rotor
Run Time 30sec to 99min Hold (Continuous Operation)
Acceleration Time Increase-20s, 20s and Decrease-13s, 20s or 90s
Motor Type Brushless DC motor
Power Supply Single-phase, 100V to 240V, 50Hz/60Hz, 3A 70W
Dimension (D×W×H) 354mm×304mm×215mm
Weight 6 kg

Features

Easy operation with intuitive menu

Easy-to-read display

Speed can be set in /

Maintenance-free brushless DC motor

Quick spin function with press and hold pulse key

Lid with electric lock and automatic release function

Automatic lid-lock release after running

Braking time 2 steps adjustable only

Dual protection housing for safe running

Gentle braking with efficient separation

CE marked, cTÜVus, and passed explosion-proof test

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.