Introduction
A UV absorption ozone meter is an instrument used to measure the ozone concentration in the air or the gas by the ultraviolet (UV) absorption method, and it is used in the environmental monitoring, the water treatment, the industry, and the many other applications. The UV absorption ozone meter measures the ozone concentration by the measurement of the absorption of the ultraviolet light by the ozone at the wavelength of 254 nanometers, following the Beer-Lambert law, and it provides the ozone concentration, expressed in the parts per million or in the milligrams per cubic meter; the UV absorption ozone meter consists of a UV light source, a sample cell, a detector, the electronics, and the display, and it provides the concentration, with features such as the zero and the span calibration; the UV absorption ozone meter is used for the monitoring of the ozone in the ambient air, for the monitoring of the ozone in the water treatment, for the monitoring of the ozone in the industrial processes, for the safety, and for many other applications, and it is an essential instrument for the ozone monitoring. UV absorption ozone meters are used in the environmental monitoring, in the water treatment, in the industry, in the safety, and for many other applications. With their UV absorption, UV absorption ozone meters are essential for the accurate ozone measurement.
UV Absorption Ozone Meter LUOM-T2010
UV absorption ozone meter is a portable unit used to measure ozone concentrations. It offers a wide detection range along with real time data recording. A built-in printer facilitates di...
Standards
ISO 13964:1998-Air quality-Determination of ozone in ambient air-Ultraviolet photometric method
ISO 10313:1993-Ambient air-Determination of the mass concentration of ozone-Chemiluminescence method
ISO 6143:2001-Gas analysis-Comparison methods for determining and checking the composition of calibration gas mixtures
Complies with the above standards, but is not limited to them.
Features
1. UV absorption ozone meter for measuring ozone gas concentration via UV absorption.
2. Non-destructive, real-time measurement with high sensitivity and fast response.
3. Suitable for industrial ozone monitoring, environmental, water treatment and research.
4. Includes UV absorption cell, light source, detector, pump and operation manual.
5. Supports ozone concentration monitoring for process control and safety compliance.
FAQ
Q1: What testing scenarios is this meter mainly applied to?
A: The UV absorption ozone meter is used in industrial ozone generation, water treatment, air purification, environmental monitoring, pharmaceutical manufacturing and research to measure ozone gas concentration in real time using ultraviolet absorption at 254 nm for process control, safety monitoring and regulatory compliance. It supports ozone generator output monitoring and control in water treatment plants, ambient air ozone monitoring for worker safety, pharmaceutical cleanroom ozone disinfection verification, food processing ozone treatment monitoring, environmental ozone level assessment, and research applications. The UV absorption method provides non-destructive, real-time measurement with high sensitivity, making it suitable for continuous ozone monitoring. It is essential for industrial, environmental, water treatment, pharmaceutical and research applications requiring real-time ozone concentration measurement for process control, safety monitoring, regulatory compliance and research, where UV absorption at 254 nm provides accurate, non-destructive, real-time ozone measurement supporting ozone generator control, worker safety, disinfection verification and environmental monitoring in industrial, water treatment and healthcare environments requiring reliable ozone gas analysis.
Q2: What standards does the meter comply with?
A: The UV absorption ozone meter follows ISO, ASTM and relevant GB/T standards for ozone measurement, including methods referencing UV absorption at 254 nm. The hardware complies with IEC 61010 laboratory safety standards and applicable electromagnetic compatibility standards. Calibration should use certified ozone reference standards or traceable calibration methods. Occupational exposure limits follow applicable regulations (e.g., OSHA, GBZ 2.1).
Q3: What is the warranty period for the whole machine and key components?
A: The whole ozone meter is covered by a 12-month warranty. The UV light source, absorption cell, detector, pump and controller are covered, while filters, tubing and fuses are consumables or accessories. Damage from improper use, corrosive gas exposure or unauthorized repair is excluded. Extended service contracts are available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained personnel familiar with ozone measurement, gas handling and safety. We provide operation manuals, training and application support. Proper calibration, gas sampling, flow control and safety procedures (ozone is a toxic gas) are important for accurate measurement and safe operation.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Calibration with certified ozone reference standards recommended every 6-12 months. UV lamp intensity and absorption cell condition checked periodically. Pump flow and filter condition verified. Routine zero and span calibration before critical measurements. Full system performance verification annually.
Q7: Are supporting consumables universal?
A: Filters, tubing, pumps and UV lamps are available from specialized suppliers, though instrument-specific parts should be verified. Long-term consumable cost is moderate depending on usage and environment.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes measurement range, flow rate, sampling system, data logging, communication and enclosure rating. Additional probes, filters and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the ozone meter and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged for industrial setup. Remote guidance is provided.
Q10: What types of gases are compatible with this equipment?
A: The UV absorption ozone meter measures ozone concentration in gas streams within the measurement range, flow rate and pressure specification. The sample gas should be clean and dry; high humidity, particulates or interfering gases may require pre-treatment. Very high ozone concentrations may require dilution. Users should follow proper ozone safety procedures (ozone is toxic, use in well-ventilated areas), calibrate regularly, maintain proper sample flow, protect the absorption cell from contamination, and verify zero with ozone-free air. The instrument should not be used in explosive or highly corrosive environments without appropriate protection. For continuous monitoring, proper sample conditioning (particulate filtration, moisture removal) is recommended to protect the optical system and ensure accurate measurements.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.