Introduction
Dynamic Temperature Control System operates within a –30℃ to 200℃ range and supports thermal regulation across research and production settings. Its pump system sustains circulation under variable loads to ensure consistent thermal output. The reinforced structure and airflow design help maintain internal stability during ambient shifts. Our Control System supports fermentation tanks, pilot lines, and test platforms requiring reliable heat transfer.
This temperature control system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Dynamic Temperature Control System is designed to deliver accurate heating and cooling to research reactors, pilot-scale processes, and energy test setups. This function helps balance thermal shifts during load changes or fluid transitions across demanding application conditions.
Specifications
| Working Temperature Range | -30℃ to 200℃ |
| Temperature Control Accuracy | ±0.5℃ |
| Temperature Display | 7-inch screen |
| Display Resolution | 0.01 |
| Cooling Water Temperature Range | 10 to 33℃ |
| Ambient Temperature Range | 5 to 35℃ |
| Cooling Capacity at -200℃ | 12000 W |
| Cooling Capacity at 100℃ | 8500 W |
| Cooling Capacity at 25℃ | 6000 W |
| Cooling Capacity at -10℃ | 4700 W |
| Cooling Capacity at -20℃ | 3400 W |
| Cooling Capacity at -30℃ | 2000 W |
| Cooling Method | Air cooling / Water cooling |
| Heating Power | 12000 W |
| Cooling Water Flow Rate | 4.0 m³/h |
| Cooling Water Interface | R₂3/4 |
| Circulating Pump Max. Pressure | 1.4 bar |
| Circulating Pump Max. Flow Rate | 45 L/min |
| Outer Circulation Interface Size | R₂3/4 |
| Noise Level | 68 dB(A) |
| Protection Grade | IP20 |
| Refrigerant | R404 A |
| Heat Transfer Fluid Filling Volume | 18 L |
| Maximum Viscosity of Heat Transfer Fluid | 30 mm²/s |
| Communication Interfaces | , RS485, Pt100 |
| Power Supply | 3 to 380V, 50Hz |
| Power Consumption | 18800 W |
| Dimensions (W × D × H) | 755 × 1300 × 1795 mm |
| Net Weight | 430 kg |
Features
Voltage-controlled safety trigger
High-viscosity flow support
Application-based mode switching
Thermal load compensation circuit
Extended runtime cooling loop
FAQs
1. Can the Dynamic Temperature Control System support multiple thermal control strategies?
Dynamic Temperature Control System offers three control modes tailored for materials, inlet, or outlet flow, providing flexibility for varied lab processes. This allows users to configure temperature logic depending on the application stage without changing equipment. It benefits scenarios where heat load varies across stages like fermentation or battery testing. Transitions between setups do not require reinstallation or external modules. The ability to modify control type mid-operation enhances adaptability. Thermal accuracy remains consistent across each mode. Settings can be changed easily through the onboard display. This helps teams work on multiple projects without reprogramming the system.
2. How does the Dynamic Temperature Control System perform in spaces with temperature instability?
Dynamic Temperature Control System uses a reinforced internal build and optimized air path to withstand ambient variations without losing flow consistency. This is ideal for labs or pilot lines lacking temperature insulation. The unit’s design maintains process performance even in environments exposed to drafts or thermal noise from adjacent equipment. No external covers or shields are required. It maintains balance even as daytime and night conditions change. Long working hours in open-layout labs don’t affect performance. There's no risk of reduced flow efficiency due to ambient drift. It stays reliable in fluctuating operating zones.
3. Is the Dynamic Temperature Control System designed for continuous long-hour use?
The Dynamic Temperature Control System is built for extended thermal runs without requiring shutdowns or flow recalibrations. It delivers uninterrupted circulation performance even during high-hour operations across multiple processing stages. This benefits batch productions that rely on uninterrupted heating or cooling over time. There's no overheating of key components even in back-to-back tasks. The pump continues moving media without pressure falloff. Users can depend on it during pilot-scale production or scale-up trials. Downtime between runs is minimized significantly. This supports round-the-clock use without flow degradation.
4. Is the Dynamic Temperature Control System suitable for temperature-sensitive formulations?
Dynamic Temperature Control System features a ramp-based temperature shift system that gradually transitions thermal values to prevent stress on reactive compounds. This function helps protect chemical integrity in sensitive materials like proteins, organic solvents, or emulsions. It avoids sharp changes that may degrade structure or trigger unwanted reactions. Users can handle flammable or delicate samples without risk of overheating. The controlled rise/fall ensures better repeatability across trials. Operators don't need extra delay circuits or safety buffers. Thermal shifts remain within gentle tolerance bands. It's well suited for pilot tests involving fragile components.
5. Can the Dynamic Temperature Control System be installed in space-constrained setups?
Dynamic Temperature Control System is vertically structured to occupy minimal floor area, making it ideal for test stations or modular pilot benches. Its interface layout supports quick connection without blocking adjacent systems. The build avoids interference with nearby sensors or data ports. This makes it easy to place in clustered lab environments. There’s no need to relocate support equipment during installation. Output and return channels are positioned for hassle-free integration. Racks and worktables can accommodate the system without custom supports. It fits easily into compact or mobile lab spaces.
6. What safety function protects the Dynamic Temperature Control System after power disturbances?
The Dynamic Temperature Control System includes a delayed restart mechanism that holds system activity until stable power is restored. This helps prevent stress from sudden current return or voltage spikes. It protects the circulation pump and electrical panel from abrupt load impact. This function is critical in areas with unstable grids or frequent surges. Users don’t need to manually reset the machine after every outage. Restart is automatic once safety thresholds are met. Equipment longevity is improved through minimized electrical stress. This feature ensures stable recovery without operational risk.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

