Introduction

Aerodynamic Particle Sizer offers a 7-step system with an additional membrane stage for complete analysis. Incorporated with a 0.5 L/min low-flow rate for optimal aerosol measurement efficiency. It features parameters like Mass Median Aerodynamic Diameter (MMAD) and Geometric Standard Deviation (GSD). Aerodynamic Particle Sizer is designed for advanced phase sampling and animal exposure evaluations.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Aerodynamic Particle Sizer is ideal for measuring airborne particulates, analyzing aerosol nanoparticles and facilitates inhalation exposure testing in animals for laboratory research.

Selection Guide

Aerodynamic Particle Sizer best suited for research and experiments requiring real-time measurement of airborne particles ranging from airborne particles ranging from 0.5 to 20 microns. Widely applied in aerosol science, environmental monitoring, pharmaceutical aerosol delivery, and filtration studies, it supports applications like inhalation research, cleanroom control, and combustion analysis. Its high-resolution sizing and velocity tracking make it suitable for experiments involving aerosol dynamics, drug delivery systems, and air quality assessments. Apart from the typical applications, its testing range can be tailored to meet specific material and performance requirements, making it a versatile and dependable tool for a wide variety of particle analysis tasks.

Specifications

Type Low-flow particle size analyzer
Principle Inertial impact
Sampling Flow Rate 0.5 L /min
Intended Purpose stage sampling, aerosol particle weighing and animal exposure testing
Number of Stages 7 stages + membrane stage
Stage 1 Cutting Diameter 5.1 μm
Stage 2 Cutting Diameter 3.1 μm
Stage 3 Cutting Diameter 1.9 μm
Stage 4 Cutting Diameter 1.2 μm
Stage 5 Cutting Diameter 0.77 μm
Stage 6 Cutting Diameter 0.50 μm
Stage 7 Cutting Diameter 0.33 μm
Calculated Parameters MMAD, GSD

Features

Wide Particle Size Range

High Sensitivity detection

Inertial Impact Mechanism

Low Sample Volume Requirement

Durable Construction

Standard Accessories

Model No.AccessoryUnitQuantity
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Membrane FilterEach1
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Collection PlatesEach7
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Flow Control ValveEach1
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Sample TubingSet1
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Calibration KitSet1
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Cleaning BrushesSet1
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:101.8pt;">Power CableEach1

FAQs

1. What is an Aerodynamic Particle Sizer

An Aerodynamic Particle Sizer is a low-flow, cascade impactor that measures aerodynamic particle size distribution for aerosol studies in toxicology and environmental monitoring.

2. How does an Aerodynamic Particle Sizer work?

An Aerodynamic Particle Sizer operates on the principle of inertial impaction, separating particles by their aerodynamic diameter across multiple stages.

3. Can Aerodynamic Particle Sizer be used in workplace air quality monitoring?

Aerodynamic Particle Sizer evaluates airborne particle size distributions to assess occupational exposure risks.

4. How does Aerodynamic Particle Sizer assist in nanomaterial safety research?

Aerodynamic Particle Sizer classifies nanoscale particles by aerodynamic size to study potential inhalation hazards.

5. What role does Aerodynamic Particle Sizer play in aerosol generator testing?

Aerodynamic Particle Sizer verifies the performance and output size distribution of aerosol generators and nebulizers.

6. Why is Aerodynamic Particle Sizer important in inhalation toxicology studies?

Aerodynamic Particle Sizer helps assess where aerosolized particles deposit in the respiratory tract by providing MMAD and GSD data.

7. Can Aerodynamic Particle Sizer help determine deposition sites in animal respiratory tracts?

Aerodynamic Particle Sizer predicts deposition zones (nasal, tracheobronchial, alveolar) based on aerodynamic diameter.

8. Can Aerodynamic Particle Sizer distinguish between respirable and non-respirable fractions?

Aerodynamic Particle Sizer separates particles by aerodynamic size, allowing clear distinction between respirable and non-respirable fractions.

9. Is Aerodynamic Particle Sizer compatible with aerosols containing biological agents or pathogens?

Aerodynamic Particle Sizer is compatible with biological aerosols when used within appropriate biosafety systems to prevent contamination and exposure.

10. What kind of maintenance does Aerodynamic Particle Sizer require?

Routine maintenance includes cleaning of cascade stages, cleaning collection substrates, checking and calibrating flow rates, and periodic inspection of seals to ensure accurate and reliable performance.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.