Introduction

An HPLC system is a high performance liquid chromatography system used for the separation, the identification, and the quantification of the components in the mixtures, and it is used in the pharmaceutical, the clinical, the food, the environmental, the chemical, and the many other applications. The HPLC system consists of a solvent delivery system with the pump, an injector, a separation column, a detector, such as the UV-visible, the fluorescence, or the refractive index detector, and a data system, and it separates the components by the pumping of the mobile phase through the column, with the components detected as they elute; the HPLC system provides features such as the gradient elution, the high resolution, and the automation, and it is used for the analysis of the pharmaceuticals and the drugs, for the analysis of the food and the beverages, for the analysis of the environmental samples, for the analysis of the biomolecules, for the quality control, for the research, and for many other applications; the HPLC system is an essential analytical system in the modern laboratories. HPLC systems are used in the pharmaceutical industry, in the clinical laboratories, in the food industry, in the environmental laboratories, in the chemical industry, and for many other applications. With their separation, HPLC systems are essential for the analysis of the complex mixtures.

HPLC System T-HLS-S2205

HPLC System T-HLS-S2205

HPLC System is an analytical system equipped with high-pressure constant flow pump. Features two solvent channels for precise and stable solvent delivery. Comes with a UV-Visible detector ...
HPLC System T-HLS-L2100

HPLC System T-HLS-L2100

HPLC System is designed with flow rate range of 0.001 to 9.999 mL/min. It features modular stack construct that allows flexible system configuration for diverse workflows. Equipped with hi...

Standards

Complies with the above standards, but is not limited to them.

Features

1. High-performance liquid chromatography system for compound separation and analysis.

2. Modular design including high-pressure pump, autosampler, column oven and detector.

3. Supports UV-Vis, fluorescence, refractive index and mass spectrometry detection.

4. Suitable for pharmaceutical, chemical, environmental, food and clinical laboratories.

5. Software supports method development, quantitation, regulatory compliance and data management.

FAQ

Q1: What testing scenarios is this system mainly applied to?

A: The HPLC system is used in pharmaceutical quality control, chemical analysis, environmental monitoring, food safety testing, clinical diagnostics and research laboratories to separate, identify and quantify compounds in complex mixtures. It supports drug potency and impurity analysis, pesticide residue testing in food, environmental pollutant monitoring, clinical biomarker measurement, natural product analysis and chemical product quality control. The high-resolution separation capability makes it the standard analytical technique for non-volatile, thermally labile compounds across industries. It is essential for pharmaceutical manufacturing quality control, regulatory compliance testing, environmental monitoring, food safety laboratories and research institutions requiring accurate, reproducible quantitative analysis of active ingredients, degradation products, contaminants and biomarkers in diverse sample matrices.

Q2: What standards does the system comply with?

A: The system supports methods referenced in USP, EP and ChP monographs, ISO and ASTM standards for specific analytes, and relevant GB/T standards for HPLC analysis. The hardware complies with IEC 61010 laboratory safety standards. Electronic records may be configured for 21 CFR Part 11 compliance. System suitability testing follows pharmacopoeial requirements.

Q3: What is the warranty period for the whole machine and key components?

A: Standard warranty is 12 months from commissioning. The pump, autosampler, detector and control system are covered, while columns, solvents, vials and seals are consumables excluded from warranty. Extended warranty and service contracts are available for this high-value system. Damage from improper solvent use or lack of maintenance is excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: HPLC operation requires specialist training in chromatography principles, method development and instrument maintenance. We provide structured operator training, application support and method consultation. Routine use by trained analysts is supported by software wizards and standard operating procedures.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: System suitability testing with reference standards should be performed before each analytical batch for regulated methods. Pump flow rate, detector wavelength and autosampler precision should be calibrated every 6-12 months. Annual preventive maintenance by a certified engineer is strongly recommended. Column performance should be monitored and columns replaced according to method requirements.

Q7: Are supporting consumables universal? What about the long-term procurement cost?

A: HPLC columns, solvents, vials and filters are available from multiple qualified suppliers, though original columns and instrument-specific seals are recommended for optimal performance. Long-term consumable and service cost is significant and should be included in the annual laboratory budget. Solvent and column costs dominate recurring expenses.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes pump type, detector configuration, autosampler capacity, column oven range and software modules. Custom orders require detailed application discussion and extend lead-time. Users should define target analytes, matrices, sensitivity requirements and throughput before configuration.

Q9: Does the purchase include on-site installation and commissioning service?

A: Yes, HPLC systems include on-site installation, commissioning and operator training by a certified application specialist. Site preparation guidance is provided before delivery to ensure the laboratory meets power, solvent storage and ventilation requirements.

Q10: What types of samples are compatible with this equipment?

A: The system analyzes liquid-soluble organic and some inorganic compounds within the column and detector capabilities. Samples must be filtered and free of particulate matter to protect the column and system. Highly viscous, strongly acidic or basic samples may require dilution or special columns. Compounds that are volatile or thermally stable may be better suited to GC analysis. Users should verify column chemistry and mobile phase compatibility for each application, and perform proper system suitability testing before reporting analytical results.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry