Introduction
HPLC System is designed with flow rate range of 0.001 to 9.999 mL/min. It features modular stack construct that allows flexible system configuration for diverse workflows. Equipped with high-pressure dual-plunger pump, it ensures stable solvent flow and gradient delivery. It incorporates temperature-controlled column oven, maintaining consistent separation conditions. Liquid Chromatograph is ideal for isolation, detection, and quantification of chemical compounds.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
HPLC System enables compound separation, detection, and quantification across pharmaceutical quality control, environmental monitoring, chemical analysis, academic research, and routine laboratory testing workflows.
Specifications
| Flow Rate Range | 0.001 to 9.999 mL/min |
| Flow Rate Error | Less than or equal to 0.5% |
| Infusion Mode | Micro-volume double plunger |
| Maximum Infusion Pressure | 6000 Psi (42 MPa) |
| Column Capacity | 2 × 250 mm chromatographic columns |
| Temperature Control Range | Room temperature +5 ℃ to 70 ℃ |
| Spectral Bandwidth | 6 nm |
| Flow Cell Volume | 8 μL |
| Wavelength Range | 190 to 700 nm |
| Optical Path | 10 mm |
| Flow Rate Stability Error | Less than or equal to 0.2% RSD |
| Gradient Error | ±1% (0 to 100% water/acetone aqueous solution) |
| Pressure Pulsation | Less than or equal to 15 Psi |
| Pump Sealing | 5400 Psi for 10 min, pressure drop Less than or equal to 400 Psi |
| Temperature Accuracy | ±1.0 ℃ |
| Temperature Stability | ±0.1 ℃ |
| Wavelength Indication Error | Less than or equal to ±1 nm |
| Wavelength Repeatability Error | Less than or equal to ±0.1 nm |
| Dynamic Noise | Less than or equal to ±0.75 × 10⁻⁵ AU (methanol, 1 mL/min, 254 nm, 20 ℃) |
| Static Noise | Less than or equal to ±0.5 × 10⁻⁵ AU (empty cell, 1 s response, 20 ℃) |
| Dynamic Baseline Drift | Less than or equal to ±1 × 10⁻⁴ AU/h (methanol, 1 mL/min, 254 nm, 20 ℃) |
| Static Baseline Drift | Less than or equal to 0.5 × 10⁻⁴ AU (empty cell, 1 s response, 20 ℃) |
| Linear Range | Greater than or equal to 10⁴ |
| Minimum Detection Concentration | Less than or equal to 1 × 10⁻⁹ g/mL |
| Qualitative Repeatability | RSD₆ Less than or equal to 0.1% |
| Quantitative Repeatability | RSD₆ Less than or equal to 0.5% |
| Dimensions | 60×260×420 mm |
| Weight | 11kg |
Features
Real-time display
UV-Vis detector
Low baseline noise
Broad linearity
Compact flow cell
Fixed optical path
Programmable interface
Standard Accessories
Model No. | Accessory name |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> High Pressure Constant Current Infusion Pump | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Manual Injection Valve | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Installation kit | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> UV-Vis Variable Wavelength Detector | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Ultrasonic Cleaner | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Software Workstation | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Special Column for Furfural | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Centrifuge | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Computer | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Vortex Oscillator | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:333.0pt;"> Printer |
FAQs
1. What is a calibration curve in HPLC?
It is a graph that plots the known concentrations of a standard compound versus the detector response.
2. Is pH important in HPLC?
The pH of the mobile phase plays a crucial role in analyzing ionizable compounds.
3. Can HPLC be used for biomolecule analysis?
It is widely used for separation and analysis of biomolecules such as proteins, peptides and nucleic acids.
4. What is meant by elution strength in HPLC?
It refers to the ability of the mobile phase to elute the analytes from the stationary phase.
5. What is a HPLC?
A HPLC is an apparatus designed to separate, identify and quantify the components of a complex mixture.
6. On what principle is HPLC based on?
It is based on the differential interactions between the analytes and the stationary phase.
7. What is meant by resolution in HPLC?
Resolution refers to the ability of the system to separate two peaks.
8. What is meant by retention time in case of HPLC?
It is the time taken by specific compound to travel through the HPLC column and reach the detector.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.