Introduction

Tissue Embedding System has a paraffin chamber with a super large capacity of 4L allowing for the embedding of a large number of specimens simultaneously. It is a fully programmable computer control unit that allows for automatic system start and stop at any time. An with icons is equipped with advancedin the system to indicate the current working status. Our system includes a paraffin chamber, paraffin dispenser, left and right thermal storage compartments, and a heating plate.

This tissue embedding system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Tissue Embedding System is used for the preparation of biological tissue samples by embedding them in paraffin. It is commonly employed in histopathology laboratories within hospitals, research institutions, and diagnostic centers.

Specifications

Paraffin Chamber Capacity 4L
Paraffin Chamber Temperature Range RT to 85℃
Paraffin Dispenser Temperature Range RT to 85℃
Working Plate Temperature Range RT to 85℃
Temperature Control Precision ± 1%
Forceps Wells Temperature Range RT to 85℃
Paraffin Flow Control Finger touch plate Optional foot pedal
Paraffin Chamber Power 1000W
Paraffin Chamber Power Supply AC220V/ AC110V ± 10% 50Hz/60Hz
Paraffin Chamber Working Plate Size 155mm × 90mm
Paraffin Chamber Dimension (W × D × H) 670 × 590 × 445 mm
Paraffin Chamber Net Weight 33 Kg
Cryo Module Temperature Range RT to -20℃
Cryo Module Temperature Setting -15℃
Cryo Module Power 300W
Cryo Module Small Cold Plate Size 60mm ×50mm
Cryo Module Large Cold Plate Size 340mm × 322mm
Cryo Module Dimension (W × D × H) 685 × 380 × 430mm
Cryo Module Net Weight 26 Kg
Thermal Storage Plate Temperature Range RT to 85℃
Thermal Storage Compartment Capacity 4.5L
Conserving Table Power 180W
Conserving Table Dimension (W × D × H) 620 × 380 × 425mm
Conserving Table Net Weight 15 Kg

Features

Temperature-sensing blocks

Five temperature-control channels

Multiple overheating protection mechanisms

Automatic memory and restoration functions

A safe and reliable low-voltage illumination system

FAQs

1. What are the key factors to consider when selecting this tissue embedding system for laboratory use?

When selecting this tissue embedding system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this tissue embedding system be calibrated to ensure accurate results?

It is recommended to calibrate this tissue embedding system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this tissue embedding system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this tissue embedding system be used with different types of samples, and are there any compatibility considerations?

Yes, this tissue embedding system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the tissue embedding system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.