Introduction

Semi-automatic Microtome is a semi-automated unit with manual functionality for user convenience. Designed with built-in actuation system for precise tissue slicing, safety alarm system alert the user for fault diagnosis.

This microtome is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Semi-automatic Microtome widely used for sectioning (slicing, trimming) of biological specimens across Histopathology, Medicine filed for research and analysis.

Specifications

Slice thickness range 0.5 µm to 100 µm (3 µm to 5 µm best slicing effect)
Trimming section range 1 µm to 600 µm
Horizontal specimen stroke 20 mm
Vertical specimen stroke 55 mm
Maximal slice section 50×45 mm
Specimen retraction 20 µm
Slip precision ± 5 %
Section thickness setting 0.5 to 5 µm, in 0.5 µm increment
5 to 20 µm, in 1 µm increment
20 to 60 µm, in 5 µm increment
60 to 100 µm, in 10 µm increment
Trimming thickness setting 1 to 10 µm, in 1 µm increment
10 to 20 µm, in 2 µm increment
20 to 50 µm, in 5 µm increment
50 to 100 µm, in 10 µm increment
100 to 600 µm, in 50 µm increment
Packing Dimension 680×560×480 mm
Gross Weight 50 kg

Features

screen shows the slice and trimming thickness

Adopted with advanced imported actuation system, for more precise tissue slicing

Sample retraction for prevention of sample damage

Can lock hand wheel in any position

Easy to disassembled waste bath

Safety alarm to alert the user for fault diagnosis

FAQs

1. What are the key factors to consider when selecting this microtome for laboratory use?

When selecting this microtome, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this microtome be calibrated to ensure accurate results?

It is recommended to calibrate this microtome at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this microtome?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this microtome be used with different types of samples, and are there any compatibility considerations?

Yes, this microtome can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the microtome malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.