Introduction

Advanced Thermal Cycler boasts cutting-edge Peltier-based technology, ensuring precise and consistent thermal performance. Its customizable ramping rate enhances user efficiency by reducing processing time. The programmable Gradient feature facilitates precise annealing temperature determination. With unrestricted access via USB Flash Drive or LAN interface, convenience is paramount. The automatic shut-off/start functionality aligns with safety standards. The Digital LCD screen offers real-time graphical monitoring of each stage. This versatile instrument finds wide-ranging applications in nucleic acid amplification, genotyping, mutagenesis, and various research endeavors.

Advanced Gradient Thermal Cycler T-S2G-C101

Advanced Gradient Thermal Cycler T-S2G-C101

Advanced Gradient Thermal Cycler designed to offers 6×16×0.2 ml capacity and 0.2 ml tubes to 96-well plate holders. It features maximum heating rate of 6 °C/s. Incorporates mobile opera...
Advanced Gradient Thermal Cycler T-S2G-C102

Advanced Gradient Thermal Cycler T-S2G-C102

Advanced Gradient Thermal Cycler operates with a maximum temperature of 105°C and has a capacity of 96 wells, each with a volume of 0.2 ml. It features a gradient spread from 1 to 42 °C ...
Advanced Gradient Thermal Cycler T-S2G-C402

Advanced Gradient Thermal Cycler T-S2G-C402

Advanced Gradient Thermal Cycler operates with 64×0.2 ml and 32×0.2ml aluminum plates using anodizing technology. It features an automatic tightening and closing hot lid. Integrated andr...
Advanced Gradient Thermal Cycler T-S2G-C501

Advanced Gradient Thermal Cycler T-S2G-C501

Advanced Gradient Thermal Cycler is designed with 64×0.2 ml and 32×0.2 ml capacity and maximum heating rate of 8°C/s. It offers an Android operating system and 11 pre-installed program ...
Advanced Gradient Thermal Cycler T-S2G-C401

Advanced Gradient Thermal Cycler T-S2G-C401

Advanced Gradient Thermal Cycler is programmed with an Android operating system and 11 pre-installed standard program patterns. Integrated with Peltier heating units, it has an automatic t...
Advanced Gradient Thermal Cycler T-S2G-C201

Advanced Gradient Thermal Cycler T-S2G-C201

Advanced Gradient Thermal Cycler is designed to supports PCR runs with 6×16×0.2 ml capacity and maximum heating rate of 5°C/s. It features an android system with 11 pre-installed progra...
Advanced Gradient Thermal Cycler T-S2G-C202

Advanced Gradient Thermal Cycler T-S2G-C202

Advanced Gradient Thermal Cycler offer 96×0.2 ml capacity with 11 pre-installed programs. It features Corrosion-resistant aluminum built and Android OS. Equipped with Automatic Tightening...
Advanced Gradient Thermal Cycler T-S2G-C301

Advanced Gradient Thermal Cycler T-S2G-C301

Advanced Gradient Thermal Cycler is designed with an Android operating system. Incorporated anodizing technology supports PCR runs on 384-well aluminum plates. Equipped with Peltier heatin...
Advanced Thermal Cycler (Gradient) T-S2T-L2101

Advanced Thermal Cycler (Gradient) T-S2T-L2101

Advanced Thermal Cycler (Gradient) wide temperature range from 0°C to 99°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Equipped wi...
Advanced Thermal Cycler (Gradient) T-S2T-L2200

Advanced Thermal Cycler (Gradient) T-S2T-L2200

Advanced Thermal Cycler (Gradient) B200 features wide temperature range from 0°C to 100°C. It features dual block configuration with 48 wells for 0.2 mL tubes and 48 wells for 0.5 mL tub...
Advanced Thermal Cycler (Gradient) T-S2T-L2201

Advanced Thermal Cycler (Gradient) T-S2T-L2201

Advanced Thermal Cycler (Gradient) B201 features wide temperature range from 0°C to 100°C. It features dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tub...
Advanced Thermal Cycler (Basic) T-S2T-S2201

Advanced Thermal Cycler (Basic) T-S2T-S2201

Advanced Thermal Cycler (Basic) features wide temperature range from 0°C to 100°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Intu...
Advanced Thermal Cycler (Gradient) T-S2T-L2100

Advanced Thermal Cycler (Gradient) T-S2T-L2100

Advanced Thermal Cycler (Gradient) wide temperature range from 0°C to 99°C. It supports dual block configuration with 48 wells for 0.2 ml tubes and 48 wells for 0.5 ml tubes. Equipped wi...
Advanced Thermal Cycler (Basic) T-S2T-S2101

Advanced Thermal Cycler (Basic) T-S2T-S2101

Advanced Thermal Cycler (Basic) features wide temperature range from 0°C to 99°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Equip...
Advanced Thermal Cycler (Basic) T-S2T-S2100

Advanced Thermal Cycler (Basic) T-S2T-S2100

Advanced Thermal Cycler (Basic) features wide temperature range from 0°C to 99°C. It supports dual block configuration with 48 wells for 0.2 mL tubes and 48 wells for 0.5 mL tubes. Intui...

Standards

ISO 20836:2021-Microbiology of the food chain-PCR for the detection of microorganisms-Thermal performance testing of thermal cyclers

Complies with the above standards, but is not limited to them.

Features

1. Precise thermal or optical control supports accurate results.

2. Fast block ramps shorten overall protocol time.

3. Clear display or software shows run status and data.

4. Uniform block temperature supports well-to-well consistency.

5. Programmable protocols store cycling or imaging steps.

FAQ

What is the Advanced Thermal Cycler mainly used for?

The Advanced Thermal Cycler is used in molecular and cell biology for amplification, separation, imaging or sample preparation. It supports PCR, electrophoresis, nucleic-acid work and related research and diagnostic laboratories.

What standards does the Advanced Thermal Cycler comply with?

The instrument is designed with reference to IEC 61010 electrical safety, applicable molecular-biology methods and relevant GB/T standards. Programs and reagents should follow validated protocols. Compliance documentation can be provided on request.

What warranty comes with the Advanced Thermal Cycler?

We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.

Is the Advanced Thermal Cycler difficult to operate?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Where do we get replacement parts?

Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.

Are options or configurations available?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Advanced Thermal Cycler?

Do not use contaminated samples or reagents, skip controls or block thermal or optical paths. Prevent cross-contamination and maintain calibration. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry