Introduction
Auto Chemistry Analyzer is designed to process 180 tests per hour. Features 30 sample positions and 60 reagent positions for high-volume laboratory workflow. Equipped with an independent mixing bar made of Teflon-treated material to avoid liquid hanging. Incorporates refrigerated compartments for reagents and samples to maintain stability. Auto Chemistry Analyzer ensures biochemical tests in clinics, labs, hospitals, and pharmaceutical settings.
Calibrated according to national metrology standards, ensuring measurement accuracy and traceability. The instrument has passed CE certification, suitable for use in international markets.
Applications
Auto Chemistry Analyzer is ideal for biochemical analysis in clinical labs, research centers, hospitals, and pharmaceutical industries for diagnosis, monitoring, and quality control of patient samples and experimental assays.
Selection Guide
Auto Chemistry Analyzer the best for clinical diagnostics, pharmaceutical research, and biochemical experiments requiring accurate, high-throughput analysis of blood, serum, plasma, and other body fluids. This fully automated system is best suited for research studies that demand reliable quantification of multiple analytes, such as glucose, urea, creatinine, and liver function markers. Its efficient sample handling and reagent management make it valuable for labs operating under GLP and GMP standards. With user-friendly software and consistent performance, it supports routine testing in hospital laboratories, academic research facilities, and pharmaceutical quality control labs. Customers should consider this model when their experiments require speed, accuracy, and minimal manual intervention.
Specifications
| Throughput | 180 tests per hour |
| Sample Capacity | 2 to 30μl |
| Reagent Capacity | 20 to 300μl |
| Reagent Bottle Compatibility | 15ml, 20ml, 30ml, 50ml, 60ml, 70ml |
| Minimum Reaction Volume | 150µl |
| Maximum Reaction Time | 15 minutes |
| Reagent Position | 30 |
| Sample Position | 60 |
| Working Mode | Discrete/random access |
| Test Principle | Absorbance photometry, Turbidimetry |
| Methodology | End-point, Fixed-time, Kinetic, Single/Dual reagent chemistries, monochromatic/bichromatic |
| Calibration | Linear and nonlinear, Logit-4P, Logit-5P, Spline, exponent, polynomial |
| Linear Absorbance Range | 0 to 3.8Abs |
| Wavelengths | 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm |
| Quality Control Charts | L-J, Cumulative, Twin Plot |
| Reaction Temperature | 37 ± 0.2℃ |
| Reagent Storage Temperature Range | 4 to 16℃ |
| Ambient Temperature | 10 to 30℃ |
| Temperature Fluctuation | 0.1℃ |
| Humidity | Less than or equal to 85% |
| Maximum Water Consumption | Less than 12L |
| Cuvettes Material | Plastics (quartz glass can be selected) |
| Probe Cleaning | Automatic washing for both interior and exterior |
| Carry-Over | Less than 0.1% |
| Power Consumption | 600W |
| Power Supply | 200 to 240V 50/60HZ |
| Dimension | 834×643×756 mm |
| Net Weight | 65Kg |
| Gross Weight | 91Kg |
| Repeatability | ≤2% RSD |
Features
Collision protection
Equipped with RS232/USB communication interface for data export and remote control. Supports connection to laboratory information management system (LIMS) for centralized data management and traceability.
RS-232 interface
Endpoint checking
Polished probe walls
Reversed optic system
FAQs
1. What is an Auto Chemistry Analyzer
An Auto Chemistry Analyzer is a fully automated tabletop device designed for high-throughput biochemical analysis in clinical laboratories.
2. How does Auto Chemistry Analyzer work?
Auto Chemistry Analyzer works on the principle of photometry.
3. How is Auto Chemistry Analyzer used in clinical diagnostics?
Auto Chemistry Analyzer measures blood and urine analytes like glucose, urea, and creatinine for disease diagnosis.
4. How does Auto Chemistry Analyzer help in electrolyte balance testing?
Auto Chemistry Analyzer accurately quantifies sodium, potassium, chloride, and calcium to detect electrolyte imbalances.
5. What role does Auto Chemistry Analyzer play in anemia investigations?
Auto Chemistry Analyzer helps by measuring iron, ferritin, and total protein levels to assess nutritional anemia.
6. How is Auto Chemistry Analyzer applied in metabolic disorder screening?
Auto Chemistry Analyzer measures analytes like glucose, lipids, and ketones to identify metabolic imbalances.
7. Can Auto Chemistry Analyzer analyze bilirubin levels for jaundice diagnosis?
Auto Chemistry Analyzer accurately measures total and direct bilirubin levels in patient samples.
8. How does Auto Chemistry Analyzer assist in nutrition studies?
Auto Chemistry Analyzer evaluates protein, albumin, and lipid levels to assess nutritional status.
9. Can Auto Chemistry Analyzer be used in pediatric diagnostics?
Auto Chemistry Analyzer accurately analyzes small-volume samples, making it ideal for pediatric patients.
10. What kind of maintenance does Auto Chemistry Analyzer require?
Routine maintenance includes cleaning the cuvettes and probes, performing calibration and checking reagents to ensure accurate and reliable performance.
11. What is an Auto Chemistry Analyzer?
An Auto Chemistry Analyzer is an apparatus designed to perform chemical analyses on biological samples.
12. What types of tests can be performed using Auto Chemistry Analyzer?
It can perform a wide range of clinical tests such as systems to prevent contamination.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.