Introduction

Single Beam Visible Spectrophotometer delivers reliable absorbance and transmittance measurements across visible spectrum. They feature single-beam optical path with advanced monochromator and high-quality diffraction gratings. These Spectrophotometers provide efficient photometric analysis, multiple scanning modes, and clear visual interface. Their compact structure, stable output, and intuitive controls simplify routine spectroscopic tasks. Spectrophotometer offers consistent readings, flexible data transfer, and durable performance for streamlined workflows.

Single Beam Visible Spectrophotometer T-SV-L2100

Single Beam Visible Spectrophotometer T-SV-L2100

Single Beam Visible Spectrophotometer has wavelength range of 325 to 1000 nm. It features lower stray light and better photometric performance for reliable analysis across spectrum. Equipp...
Single Beam Visible Spectrophotometer T-SV-L2101

Single Beam Visible Spectrophotometer T-SV-L2101

Single Beam Visible Spectrophotometer is designed with wavelength range of 325 to 1000 nm. It features microprocessor system for enhanced control, reliable performance, and stable operatio...
Single Beam Visible Spectrophotometer T-SV-S2101

Single Beam Visible Spectrophotometer T-SV-S2101

Single Beam Visible Spectrophotometer features wavelength range of 320 to 1100 nm. It is built with, single-beam optical system, advanced microcomputer technology, and electronic control. ...
Single Beam Visible Spectrophotometer T-SV-S2102

Single Beam Visible Spectrophotometer T-SV-S2102

Single Beam Visible Spectrophotometer within wavelength range of 320 to 1020nm. Features single-beam optical system designed for efficient and stable performance. Incorporates narrow, refi...
Single Beam Visible Spectrophotometer T-SV-S2301

Single Beam Visible Spectrophotometer T-SV-S2301

Single Beam Visible Spectrophotometer offers wavelength range from 350 to 1020 nm. Features 5 nm spectral bandwidth for routine sample testing in visible region. Equipped with tungsten lam...
Single Beam Visible Spectrophotometer T-SV-S2302

Single Beam Visible Spectrophotometer T-SV-S2302

Single Beam Visible Spectrophotometer features spectral bandwidth of 6nm. It covers wavelength range from 350 to 1020 nm with manual adjustment for operational flexibility. Integrated with...
Single Beam Visible Spectrophotometer T-SV-S2300

Single Beam Visible Spectrophotometer T-SV-S2300

Single Beam Visible Spectrophotometer operates over wavelength span of 320 to 1100 nm. Equipped with 2 nm bandwidth, it delivers high spectral resolution for routine analysis. It features ...
Single Beam Visible Spectrophotometer T-SV-S2205

Single Beam Visible Spectrophotometer T-SV-S2205

Single Beam Visible Spectrophotometer offers reliable wavelength analysis from 320 nm to 1100 nm. Built with single-beam optical system with C-T monochromator and blazed holographic gratin...
Single Beam Visible Spectrophotometer T-SV-S2202

Single Beam Visible Spectrophotometer T-SV-S2202

Single Beam Visible Spectrophotometer features 2 nm spectral bandwidth for reliable photometric performance. It supports wavelength range from 320 to 1100 nm with automatic setting functio...
Single Beam Visible Spectrophotometer T-SV-S2100

Single Beam Visible Spectrophotometer T-SV-S2100

Single Beam Visible Spectrophotometer covers wavelength range of 320 to 1100 nm. Built with 2nm spectral bandwidth and high-resolution optical system for reliable output. Incorporates impo...
Single Beam Visible Spectrophotometer T-SV-S2201

Single Beam Visible Spectrophotometer T-SV-S2201

Single Beam Visible Spectrophotometer 4 nm spectral bandwidth to support routine absorbance analysis. Designed to cover wavelength range from 320 to 1050nm, for visible light measurements....
Single Beam Visible Spectrophotometer T-SV-S2203

Single Beam Visible Spectrophotometer T-SV-S2203

Single Beam Visible Spectrophotometer operates over a wavelength range of 320 to 1100 nm. Built with 2nm spectral bandwidth, it enables standard-resolution measurements for visible range a...
Single Beam Visible Spectrophotometer T-SV-S2204

Single Beam Visible Spectrophotometer T-SV-S2204

Single Beam Visible Spectrophotometer operates across 320 to 1100 nm wavelength range. Features 4 nm spectral bandwidth and C-T monochromator with blazed holographic grating. Designed with...

Standards

GB/T 26798-2010-Single-beam ultraviolet-visible spectrophotometers

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

USP General Chapter <857>-Ultraviolet-Visible Spectroscopy

Complies with the above standards, but is not limited to them.

Features

1. Multi-cell or sipper options increase measurement throughput.

2. USB, RS232 or printer options export results and reports.

3. Multiple modes support absorbance, transmittance, concentration and kinetics.

4. Cuvette holders and accessories suit different sample types.

5. Clear digital or software interface simplifies measurement and data handling.

FAQ

What are the main applications of the Single Beam Visible Spectrophotometer?

The Single Beam Visible Spectrophotometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

What standards does the Single Beam Visible Spectrophotometer comply with?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

What does the warranty cover?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

How easy is the Single Beam Visible Spectrophotometer to use?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Single Beam Visible Spectrophotometer need calibration or verification?

To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.

Are consumables and spare parts easy to obtain?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Are options or configurations available?

The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.

Is installation and commissioning included?

Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.

What maintenance and safety points matter?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry