Introduction

Single Jacketed Reactors are advanced systems designed to provide precise control over chemical reactions under optimal conditions. They offer a wide range of capacities to meet various process requirements. These units operate across a broad temperature range, delivering precise control with high accuracy. They feature adjustable stirring speeds, ensuring optimal performance with reliable motor support. They have vacuum compatibility for creating controlled environments and ensuring efficient reaction processes. jacketed reactors are built with robust single-layer borosilicate glass, offering durability.

Single Glass Jacketed Reactor T-S279SGR

Single Glass Jacketed Reactor T-S279SGR


Single Glass Jacketed Reactor features a generous 100 L capacity, making it ideal for large-scale chemical processes. It operates within a broad temperature range of -80 °C to +250 °C, ...
Single Glass Jacketed Reactor T-S276SGR

Single Glass Jacketed Reactor T-S276SGR


Single Glass Jacketed Reactor features a 20 L high-grade borosilicate glass vessel, offering ample capacity to perform a wide range of chemical reactions. It provides an adjustable stirri...
Single Glass Jacketed Reactor T-S277SGR

Single Glass Jacketed Reactor T-S277SGR


Single Glass Jacketed Reactor features a 30 L vessel to accommodate a wide range of chemical reactions. It features a stirring speed range of 0 to 450 rpm, ensuring optimal and uniform mi...
Single Glass Jacketed Reactor T-S278SGR

Single Glass Jacketed Reactor T-S278SGR


Single Glass Jacketed Reactor features a precise stirring speed range of 0 to 450 rpm, enabling uniform mixing and optimal reaction. It features a generous 50 L glass vessel, providing am...
Single Glass Jacketed Reactor T-S275SGR

Single Glass Jacketed Reactor T-S275SGR


Single Glass Jacketed Reactor features a 10 L capacity, offering ample volume to accommodate a wide range of sample types. It provides a wide temperature range from -80 °C to +250 °C, e...
Single Glass Jacketed Reactor T-S274SGR

Single Glass Jacketed Reactor T-S274SGR


Single Glass Jacketed Reactor is designed with a 5 L glass vessel, providing ample space for conducting larger-scale reactions with enhanced accuracy. It operates with a vacuum degree of ...
Single Glass Jacketed Reactor T-S273SGR

Single Glass Jacketed Reactor T-S273SGR


Single Glass Jacketed Reactor features a 3 L capacity, ensuring excellent chemical resistance and thermal stability. It operates within a temperature range of -80 °C to +250 °C, provi...
Single Glass Jacketed Reactor T-S271SGR

Single Glass Jacketed Reactor T-S271SGR


Single Glass Jacketed Reactor is designed with a 1L high-quality glass vessel to deliver optimal results in chemical synthesis. It operates within a wide temperature range from -80℃ to +...
Single Glass Jacketed Reactor T-S272SGR

Single Glass Jacketed Reactor T-S272SGR


Single Glass Jacketed Reactor supports a stirring speed range of 0 to 450 rpm, enabling consistent mixing. It features a 2 L glass vessel, providing ample capacity to ensure accurate and ...

Standards

ISO 3585:1998-Borosilicate glass 3.3-Properties

Complies with the above standards, but is not limited to them.

Features

1. Integrated heating and control support repeatable procedures.

2. Multiple sample positions improve throughput.

3. Integrated cooling or reflux improves recovery and safety.

4. Standard glass assemblies follow common analytical methods.

5. Clear controls show temperature and time.

FAQ

What are the main applications of the Single Glass Jacketed Reactor?

The Single Glass Jacketed Reactor is used for a defined chemical preparation step such as digestion, extraction, evaporation or distillation. It supports analytical, environmental, food, pharmaceutical and teaching laboratories following standard procedures.

What standards does the Single Glass Jacketed Reactor comply with?

The apparatus is designed with reference to IEC 61010 electrical safety and relevant ISO and GB/T standard methods for the specific procedure. Glassware and heating must match the method. Compliance documentation can be provided on request.

What warranty comes with the Single Glass Jacketed Reactor?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

Will staff need special training?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Single Glass Jacketed Reactor be calibrated?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Are the consumables universal or proprietary?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can the Single Glass Jacketed Reactor be customised?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Do you provide on-site installation?

Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.

What maintenance and safety points matter?

Do not use incompatible or damaged glassware, exceed temperature or pressure limits or work without ventilation for fuming samples. Follow the standard method and safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry