Introduction
Confocal Microscope features plan apochromatic objectives from 10x to 100x for sharp, high-resolution imaging. Its eyepieces provide a wide, comfortable view for prolonged observations. It offers High-power lasers that ensure bright, precise excitation for accurate fluorophore imaging. The sensitive system captures fine structural details with excellent depth for clear confocal images. Our confocal microscope is widely used in life science research, cell biology, pathology, neuroscience, and materials science.
This microscope is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Confocal Microscope provides high-resolution three-dimensional imaging and multi-dimensional scanning, enabling precise visualization. It is widely used in life science research, neuroscience, and materials science laboratories for fluorescence imaging, live-cell observation, and structural analysis.
Specifications
| Objective (Plan Apochromatic Lenses) | 10x (NA 0.45, WD 4.0 mm), 20x (NA 0.75, WD 1.1 mm), 40x (NA 0.95, WD 0.19 to 0.21 mm), 60x (NA 1.42, WD 0.25 mm), 100x (NA 1.45, WD 0.13 mm) |
| Head Spectrophotometry Type | Two-level, T = 0 to 1000% |
| Interpupillary Distance | 55 to 75 mm |
| Eyepiece Magnification | 10x Adjustable |
| Field of View | 22 mm |
| Laser Wavelength | 405 nm, 488 nm, 561 nm, 640 nm |
| Laser Output Power | Greater than or equal to 20 mW per wavelength |
| Nosepiece Type | Electric 6-hole Converter with Slot |
| Nosepiece Memory Function | Brightness Memory |
| Nosepiece Lifespan | Greater than or equal to 60,000 hours |
| Stage Travel Range | 130 × 100 mm |
| Stage Size | 445 × 300 mm |
| Positioning Accuracy | 0.5 μm |
| Stage Resolution | 0.1 μm |
| Z-axis Focusing Accuracy | Less than or equal to 20 nm |
| Stage Lifting Mechanism | 3-Speed Variable |
| Fluorescence Optical Path | Double-layer |
| Fluorescence Module Turntable | 6-station Electric Turntable × 2 |
| Fluorescence Module Replacement | Detachable Modules |
| Filter Blocks | Excitation 330 to 390 nm / Emission 435 to 485 nm |
| Filter Blocks | Excitation 460 to 495 nm / Emission 510 to 550 nm |
| Filter Blocks | Excitation 528 to 553 nm / Emission 578 to 633 nm |
| Scanning Detectors | Greater than or equal to 4 + 1 Channel |
| Scanning Pinhole Adjustment | 0 to 5 AU (0 to 500 μm) Stepless |
| Image Bit Depth | 16-bit |
| Scanning Speed | Greater than or equal to 4 frames/sec at 512×512 px and Greater than or equal to 68 frames/sec at 8×256 px |
| Scanning Maximum Resolution | 8192 × 8192 pixels |
| Optical Zoom Range | 1x to 36x |
| Scanning Modes | Point, Rotation, X-Y-Z-λ-t 5D Imaging |
| Camera | chip |
| Video Inference | 12.3 MP |
| Software | Image Processing Software |
| Operating Temperature Range | 15 to 26 ℃ |
| Operating Humidity | Less than 60% RH |
| Power Supply Input | Dual 220 V ±10%, 50 Hz, 16 A |
| Dimensions | 1145 × 580 × 608 mm |
| Net Weight | 50 kg |
| Total Focus Weight | 60 kg |
| Gross Weight | 100 kg |
Features
Motorized Control System
Nanometer Focusing Accuracy
Modular Fluorescence System
High-Speed Imaging
Integrated Control Software
| Optical Path Control | Fully Electrically Controlled |
| Scanning Dimensions | X, Y, Z, λ, T 5D |
| Image Processing | Real-time Multi-color Overlay, Reconstruction |
| Measurement Parameter | Area, Length |
| Software Additional Features | Image Stitching, One-click CN/EN Interface |
FAQs
1. What are the key factors to consider when selecting this microscope for laboratory use?
When selecting this microscope, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this microscope be calibrated to ensure accurate results?
It is recommended to calibrate this microscope at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this microscope?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this microscope be used with different types of samples, and are there any compatibility considerations?
Yes, this microscope can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the microscope malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.