Introduction

Transmittance Tester has a spectral range of 400 to 1000 nm, covering visible regions. It features professional-grade software to set, store, and print transmittance data. The tester uses a high-transmittance integrating sphere with over 98% coating efficiency. Its customizable options allow users to set a measurement plan, spectrum data processing, quality inspection function, color measurement function, and print reports. Our Tester is widely used for measuring transmittance in various optical components, flat glass, filters, IR link hole coated lenses, display screens, etc. 

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Transmittance Tester is widely used to measure optical transmittance in various components such as flat glass, filters, IR ink hole-coated lenses, and display materials. It is especially suitable for testing mobile phone screens, touch panels, plastics, and silicone-based products. The detector supports both liquid and solid transmittance detection, including thin-film applications.

Specifications

Wavelength Range 400 to 1000 nm (customizable)
Transmittance Measurement Range 0 to 100%
Measurable Parameters Wavelength transmittance, average transmittance, transmittance spectrum curve, transmittance change curve over time, transmittance color, xy, , Lab, etc
Measurement Wavelength Interval 1 nm
Single Sampling Time Better than 1 second
Sample Port Size Φ3 mm (customizable)
Fiber Length Standard 0.5 m
Transmittance Accuracy Better than 1%
Test Repeatability Better than 1%
Integrating Sphere Coating Transmittance Rate At least 98%
Dark Background Subtraction Automatic
Lamp Source Life 1000 hours
Computer Interface interface
Operating Systems Windows 98/XP/2000/Vista/7/8/10

Features

Easy operation

Comply with International standards

Advanced measurement technology

Cost effective

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.