Introduction

Transmission Electron Microscope features ultra-high-resolution imaging with 0.23 nm line resolution and 20x to 1.5Mx magnification. It includes a high-brightness Schottky field emitter for a stable and bright electron beam. It has a fully eccentric 5-axis motorized goniometer, ensuring precise sample positioning. electron microscope features high-sensitivity CMOS cameras, enabling real-time analysis of fine structural details.

Applications

Transmission Electron Microscope is used to analyze nanostructures, crystal defects, and biological specimens with ultra-high resolution. It is widely applied in nanotechnology, materials science, semiconductor research, and biomedical studies.

Specifications

Magnification20x to 1.5Mx
TEM Line Resolution0.23 nm
TEM Information Limit0.2 nm
Electron SourceHigh brightness Schottky field emitter
GoniometerFully eccentric goniometer with all 5-axis motorized
CameraEMSIS XAROSA CMOS (5120 × 3840 pixels)
FEG Gun Vacuum< 1×10⁻⁶ Pa
TEM Column Vacuum< 5×10⁻⁵ Pa
StageCompu stage double-tilt holder
Beam CurrentMaximum ≥ 50nA at 200kV
Probe Current≥ 1.5nA/1mm Probe
Ripple≤ 10ppm at -200kV (≤ 40kHz)
Temperature Coefficient≤ 25ppm/ °C
Stability≤ 5ppm/10min
Filament Ripple≤ 0.1% at 3A
Filament Temperature Coefficient≤ 100 ppm/ °C
Filament Stability≤ 250 ppm/10min
Rated Output Current300uA
Filament Output Current3.6A (load less than 12)
Accelerating Voltage200 kV, Factory Aligned at 80 kV and 200 kV
Power Supply90 to 264VAC,50/60Hz,10A
Main Unit Dimension1106 × 842 ×1955mm
01 Wooden Box Dimension13000 × 10500 × 21500 mm
02 Wooden Box Dimension10000 × 8500 × 20000 mm
03 Wooden Box Dimension16500 × 16500 × 11000 mm
01 Wooden Box Weight560 kg
02 Wooden Box Weight123 kg
03 Wooden Box Weight167 kg
Gross Weight1312 kg

Features

Advanced vacuum system

Double-tilt sample holder

Low ripple stability

High-performance optics

Advanced data processing

FAQ

Q1: What is the magnification range of this microscope?
A1: The magnification range is 40× to 800× (e.g., 40× to 1000× for biological microscopes), with replaceable objectives for different observation needs.

Q2: Does it support digital imaging?
A2: No, but supports optional digital camera installation - Some models are equipped with a digital camera interface, which can be connected to a computer for image capture and analysis.

Q3: How to adjust the focus for clear observation?
A3: It has coarse and fine adjustment knobs. First use the coarse adjustment to find the sample, then use the fine adjustment to get a clear image.

Q4: What type of light source does it use?
A4: It adopts a LED light source, which has long service life (up to 50000 hours) and stable brightness, without frequent bulb replacement.

Q5: Is the microscope easy to maintain?
A5: Regular maintenance only requires wiping the lenses with lens paper and keeping the stage clean. Avoid touching the lens surface with fingers.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.