Introduction
Biochemical Incubator operates within a temperature range of 5°C to 60°C, ideal for various applications. They support sensitive cultures effectively with consistent temperature distribution and humidity control. These adjustable airflow systems allow for precise control over environmental conditions. Their alert system notifies users of deviations from set parameters, ensuring sample integrity. Our Biochemical Incubator is a reliable choice for research and quality assurance.
Biochemical Incubator T-L2I-S2200
Biochemical Incubator T-L2I-L2203
Biochemical Incubator T-L2I-L2202
Biochemical Incubator T-L2I-L2201
Biochemical Incubator T-L2I-L2200
Biochemical Incubator T-L2I-L2105
Biochemical Incubator T-L2I-L2104
Biochemical Incubator T-L2I-L2103
Biochemical Incubator T-L2I-L2101
Biochemical Incubator T-L2I-L2102
Biochemical Incubator T-L2I-L2100
Biochemical Incubator T-L2I-S2106
Biochemical Incubator T-L2I-S2105
Biochemical Incubator T-L2I-S2104
Biochemical Incubator T-L2I-S2103
Biochemical Incubator T-L2I-S2102
Biochemical Incubator T-L2I-S2101
Biochemical Incubator T-S210BCI
Biochemical Incubator equipped with a PT100 sensor for precise temperature measurements from 0 to 50 °C. It features 800 L of internal volume with three adjustable shelves for flexible a...
Biochemical Incubator BI20720
Biochemical Incubator offers dual control for cooling and heating biological samples within a range of 5°C to 60°C. It features adjustable CO₂ and O₂ levels for creating optimal condi...
Standards
ISO 11133:2014-Microbiology of food, animal feed and water-Preparation, production, storage and performance testing of culture media
Complies with the above standards, but is not limited to them.
Features
1. Natural or forced convection delivers uniform chamber temperature.
2. Precise temperature control with a digital display and clear setpoint.
3. Wide temperature range covers routine incubation and warming tasks.
4. Data logging and 220V or 110V options are available.
5. Independent safety thermostat backs up the main controller.
FAQ
What is the Biochemical Incubator mainly used for?
The Biochemical Incubator is used to maintain samples at a stable, controlled temperature for incubation, culturing, warming and general biological work. It is widely used in microbiology, clinical, food, pharmaceutical and research laboratories.
What standards does the Biochemical Incubator comply with?
The unit is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for laboratory incubators. Test and culture procedures should follow the applicable standard methods. Compliance documentation can be provided on request.
How long is the warranty period?
The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.
Will staff need special training?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Biochemical Incubator need calibration or verification?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Where do we get replacement parts?
Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.
Can it be adapted to our requirements?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
Do you provide on-site installation?
Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.
What should be avoided when using the Biochemical Incubator?
Flammable, volatile or corrosive materials should not be placed in a standard incubator, and pathogenic agents require containment. Avoid overloading and clean spills promptly. Follow laboratory safety rules.