Introduction

A semi automatic biochemistry analyzer is a biochemistry analyzer with the semi-automated operation, used for the measurement of the concentrations of the biochemical parameters in the biological samples, such as the serum and the plasma, and it is used in the clinical, the diagnostic, the research, and the many other laboratories. The semi automatic biochemistry analyzer performs the measurements by the photometric method, in which the sample and the reagents are mixed and the absorbance is measured at the specified wavelengths, and the concentrations of the parameters, such as the glucose, the cholesterol, the enzymes, and the proteins, are calculated from the calibration curves; the semi automatic biochemistry analyzer consists of a photometer, a flow cell or the cuvettes, a sample and a reagent delivery system, a temperature control system, and a control and a display unit, and it provides the results with the semi-automated operation, in which the sample and the reagents are added manually and the measurement is automated; the semi automatic biochemistry analyzer is used for the clinical chemistry tests, for the measurement of the metabolic parameters, for the diagnosis, for the monitoring, for the research, and for many other applications, and it is an essential instrument in the clinical laboratory. Semi automatic biochemistry analyzers are used in the clinical laboratories, in the diagnostic laboratories, in the research institutions, in the small hospitals, and for many other applications. With their semi-automated operation, semi automatic biochemistry analyzers are essential for the biochemical analysis.

Semi Automatic Biochemistry Analyzer T-SBA-S2102

Semi Automatic Biochemistry Analyzer T-SBA-S2102

Semi Automatic Biochemistry Analyzer offers sample volume of up to 6000 µL. It features Linux operating system with color graphical interface and large LCD for smooth visualization. Equip...
Semi Automatic Biochemistry Analyzer T-SBA-S2101

Semi Automatic Biochemistry Analyzer T-SBA-S2101

Semi Automatic Biochemistry Analyzer has sample volume range of 0 to 3000 µL. It features color LCD touch screen for simple navigation and effortless operation. Equipped with clearly arra...
Semi Automatic Biochemistry Analyzer T-SBA-S2100

Semi Automatic Biochemistry Analyzer T-SBA-S2100

Semi Automatic Biochemistry Analyzer requires minimal volume of 32 µL only. It features multiple testing modes, including Endpoint, Fixed-time, Kinetics, and Absorbance for versatile anal...
Semi-Automatic Biochemistry Analyzer T-S210SABA

Semi-Automatic Biochemistry Analyzer T-S210SABA


Semi-Automatic Biochemistry Analyzer features an absorbance range from - 0.3 to 3.0 for accurate measurements. It features a halogen lamp for stable light across 340, 405, 510, 546, 578, ...

Standards

IEC 61010-2-081:2015-Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes

IEC 61010-2-101:2018-Particular requirements for in vitro diagnostic (IVD) medical equipment

ISO 15189:2022-Medical laboratories-Requirements for quality and competence

Complies with the above standards, but is not limited to them.

Features

1. Semi-automatic biochemistry analyzer for clinical chemistry testing of blood serum and plasma.

2. Supports colorimetric, kinetic and endpoint methods for routine biochemical parameters.

3. Built-in incubator and flow cell measurement provide accurate and reproducible results.

4. Suitable for small clinics, hospitals, veterinary labs and point-of-care testing facilities.

5. User-friendly interface with pre-programmed test parameters and quality control functions.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The semi-automatic biochemistry analyzer is used in small clinics, hospitals, veterinary laboratories, research facilities and point-of-care settings for routine clinical chemistry testing. It supports measurement of liver function, kidney function, blood glucose, lipids, proteins, electrolytes and other biochemical parameters in serum, plasma and other biological fluids. The semi-automatic design requires manual sample and reagent pipetting but provides automated incubation, mixing and measurement, making it suitable for low-to-medium volume testing environments where a fully automated system is not cost-effective or where space is limited.

Q2: What standards does the instrument comply with?

A: The analyzer is designed with reference to IEC 61010 laboratory electrical safety standards, ISO 15189 for medical laboratory quality where applicable, and relevant GB/T standards for clinical laboratory equipment. Test methods follow manufacturer-recommended procedures and reagent specifications. Users should verify performance with quality control materials.

Q3: What is the warranty period for the whole machine and key components?

A: The whole analyzer is covered by a 12-month warranty. The optical system, incubator, pump and controller are covered, while flow cell, tubing and reagents are consumables excluded from warranty. Damage from improper cleaning, biohazard exposure or unauthorized repair is excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained laboratory personnel familiar with clinical chemistry procedures and pipetting technique. We provide an operation manual, application notes and remote guidance. Proper sample handling, reagent preparation and quality control are essential for accurate clinical results.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Calibration should be performed according to the reagent manufacturer instructions, typically with each new reagent lot or after maintenance. Quality control should be run daily or per batch as required by the laboratory quality system. Annual preventive maintenance and optical verification are recommended.

Q7: Are supporting consumables universal?

A: Reagents, calibrators and quality control materials are available from multiple diagnostic suppliers, though reagent compatibility should be verified with the instrument manufacturer. Flow cell and tubing are model-specific and should be sourced from the supplier or authorized distributor.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes test menu, language, printer and data interface. Additional accessories such as spare flow cells and tubing sets can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the analyzer and accessories with an operation manual. Remote commissioning guidance is provided. On-site installation and training are not included for standard orders but can be arranged for clinical laboratory setup projects.

Q10: What types of samples are compatible with this equipment?

A: The analyzer tests serum, plasma and other biological fluids within the test parameter ranges. Hemolyzed, lipemic or icteric samples may interfere with certain tests and should be flagged. Whole blood may require centrifugation to obtain serum or plasma before analysis. Users should follow proper sample collection, handling and storage procedures for clinical testing.