Sterilizers are used to eliminate microorganisms from laboratory and medical equipment. They are widely used in hospitals and research facilities. The system ensures hygiene control. It solves contamination risks in reusable instruments. By providing high-temperature or chemical sterilization, it ensures safety compliance.
Bacti-T20inerator Sterilizer LBCS-T2013
Bacti-Cinerator Sterilizer has a compact design and is capable of reaching a maximum temperature of 825°C. It offers a safe and convenient sterilization method that completely replaces ...
Bacti-T20inerator Sterilizer LBCS-T2012
Bacti-Cinerator Sterilizer features a compact design and is capable of reaching a maximum temperature of 825℃. It is an advanced alcohol-free sterilizing solution, perfect for inoculati...
Bacti-T20inerator Sterilizer LBCS-T2010
Bacti-Cinerator Sterilizer is a benchtop design that offers infrared thermal sterilization with a temperature of 825℃+50℃. It delivers faster sterilization, making it a highly effectiv...
Hot Air Sterilizer LHAS-T2012
Hot Air Sterilizer features storage capacity of 252L for flexible applications. Durable stainless-steel interior featuring removable and easy-to-clean shelves. Supports adjustable temper...
Hot Air Sterilizer LHAS-T2011
Hot Air Sterilizer features stainless steel chamber with storage capacity of 138L. Forced air convection ensures consistent airflow and excellent temperature uniformity throughout the ch...
Hot Air Sterilizer LHAS-T2010
Hot Air Sterilizer operates within a temperature range of RT+10 to 250℃. Transparent window made of tempered glass allows easy observation without disturbing inner environment. Equipped...
Bacti-Cinerator Sterilizer LBCS-T2011
Bacti-Cinerator Sterilizer features a compact design that employs infrared heat sterilization with 825℃+50℃. It produces no smoke or environmental pollutants, ensuring a cleaner and sa...
Bacti-T20inerator Sterilizer LBCS-T2013
Bacti-Cinerator Sterilizer provides infrared thermal sterilization and a center high temperature of 825℃ ± 50℃. It provides rapid sterilization in 5 to 7 seconds. The sterilizer is su...
Bacti-T20inerator Sterilizer LBCS-T2012
Bacti-Cinerator Sterilizer can reach a center high temperature of 825℃ ± 50℃ within approximately 10 minutes. It features a special porcelain core that does not crack in the alternati...
Glass Bead Sterilizer LGBS-T2013
Glass Bead Sterilizer operates at a temperature range of 100 to 300°C, ensuring efficient sterilization. The unit quickly heats up, reaching 300°C in just 25 minutes, making it ideal f...
Glass Bead Sterilizer LGBS-T2012
Glass Bead Sterilizer has a temperature range of 100 to 300°C, ensuring effective sterilization of various metal instruments. With a bead capacity of 150g and a temperature accuracy of ...
Glass Bead Sterilizer LGBS-T2011
Glass Bead Sterilizer is designed to operate within temperature ranges from 100 to 300℃. It features a capacity of 300 g accommodating various small surgical instruments for effective s...
UV Water Sterilizer LAWS-T2010
UV Water Sterilizer offers a water treatment flow rate of 90 m³/hour. Enhanced with rate of up to 99.9%. Effective against a diverse range of bacteria, viruses, and algae. This steriliz...
Heat Sterilizer LHSR-T2010
Heat Sterilizer is engineered to guarantee the sterility of medical, laboratory, and other heat-resistant items by employing high-pressure saturated steam to sterilize equipment. Our ste...
UV Air Sterilizer LUAS-T2012
UV Air Sterilizer is a space-saving sterilizer utilizes air purifying technology for air sterilization and purification to effectively clean the air. Our sterilizer offers 2000 m³/h of ...
Bacti-T20inerator Loop Sterilizer LBCS-T2011
Bacti-cinerator achieves full sterilization of inoculating loops and needles in only 5 to 7 seconds. It can accommodate sterilization goods with a maximum outer diameter of φ35mm. The s...
Aquatics UV Sterilizer LAUS-T2010
Aquatics UV Sterilizer uses ultraviolet light to annihilate harmful pathogens with surgical precision, meeting highest standards of purity. It is a durable device with minimum maintenanc...
Bacti-T20inerator Sterilizer LBCS-T2010
Bacti-Cinerator Sterilizer is an easy-to-use benchtop sterilizing unit that use IR heat for organic material incineration. Sterilization takes 5 to 7 seconds at an optimum sterilizing te...
Glass Bead Sterilizer LGBS-T2010
Glass Bead Sterilizer is reliable for sterilization of small surgical instruments using glass beads. Digital control with a temperature range of 100 ℃ to 300 ℃. Sterilizer does not req...
UV Air Sterilizer LUAS-T2011
UV Air Sterilizer is a portable UV air sterilizer with air purifying technology offers working temperature range from 0 to 39℃ with air circulation of ≥800 m3/h. Features air dynamic d...
UV Air Sterilizer LUAS-T2010
UV Air Sterilizer is a portable UV air sterilizer with air purifying technology offers working temperature range from 0 to 39℃ with air circulation of ≥600 m3/h. Features air dynamic d...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
Complies with the above standards, but is not limited to them.
Features
1. Digital display shows temperature, pressure and cycle stage.
2. Over-pressure, over-temperature and low-water protection included.
3. Pressure and temperature safety devices protect operators.
4. Printer or data-logger option provides cycle records.
5. Stainless chamber resists corrosion and is easy to clean.
FAQ
What is the Sterilizer mainly used for?
The Sterilizer is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.
Which standards and regulations apply to the Sterilizer?
The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.
What does the warranty cover?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
Is the Sterilizer difficult to operate?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Are consumables and spare parts easy to obtain?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Are options or configurations available?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
How is the Sterilizer commissioned?
Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.
What maintenance and safety points matter?
Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.