Introduction

UV Water Sterilizer offers a water treatment flow rate of 90 m³/hour. Enhanced with rate of up to 99.9%. Effective against a diverse range of bacteria, viruses, and algae.

This sterilizers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Hospitals and Healthcare Facilities
Pharmaceutical Industry
Wastewater Treatment Plants
Food and Beverage Industry

Specifications

Water Treatment Flow Rate 90 m³/hour
Raw Water Source Wastes water
Water Inlet-Outlet Size 8’ inch
UV Sterilizer Material 316 stainless steel
UV Lamp Power 1350 Watts
Working Pressure 10 bar
UV Lamp Shelf Life 9000 hours
Quartz Sleeve Transmittance ≥90%
Bactericidal Efficiency ≥98%
Control Cabinet (Indoor) Carbon Steel, Wall Mount
Lamps Sleeves Quartz
Lamp 18 × 75W
Motor Power 180W
Power Supply 220V/50Hz
Reactor Dimension 1420 × 470 × 700 mm
Controlling Cabinet Dimension 1030 × 220 × 220 mm
UV Lamp Dimension 1050 × 500 × 1500 mm
Reactor Weight 150 Kg
Controlling Cabinet Weight 10 Kg
UV Lamp Weight 120 Kg

Features

Automatic cleaning mechanism

Lamp failure alert system

Observation hole provided

316L stainless steel body

Epoxy-painted control panel

Sewage discharge point included

One-piece microprocessor controller

Highly accurate UV sensor and photodiode sensor

FAQs

1. What are the key factors to consider when selecting this sterilizers for laboratory use?

When selecting this sterilizers, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this sterilizers be calibrated to ensure accurate results?

It is recommended to calibrate this sterilizers at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this sterilizers?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this sterilizers be used with different types of samples, and are there any compatibility considerations?

Yes, this sterilizers can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the sterilizers malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.