Introduction
Steam Sterilizers range includes bench top and portable steam sterilizer models. They are designed with high-pressure steam to effectively eliminate microorganisms. Their compact design maximizes space efficiency while providing powerful sterilization performance. They offer precise temperature and pressure control to ensure reliable results. Our Steam Sterilizers are ideal for laboratories, medical facilities, and research institutes.
Portable Steam Sterilizer PS2053
Portable Steam Sterilizer features an overpressure self-discharge system ranging from 0.145 to 0.165 MPa. It features a maximum operating temperature of 126°C to 128°C, and includes a u...
Bench Top Steam Sterilizer BS2054
Bench Top Steam Sterilizer is designed to provide high performance with a 50L chamber volume. It operates at a temperature of 134℃ and 0.22MPa pressure for efficient sterilization. Integ...
Bench Top Steam Sterilizer BS2053
Bench Top Steam Sterilizer is a front-loading sterilizer with 35L chamber capacity. It is operated at 134℃ under 0.22MPa pressure for effective sterilization. Built-in timer cycle range ...
Bench Top Steam Sterilizer BS2052
Bench Top Steam Sterilizer is a heavy-duty, front-loading sterilizer with an 18L capacity. It is equipped with a larger chamber opening that allows easy loading and unloading of samples. ...
Bench Top Steam Sterilizer BS2051
Bench Top Steam Sterilizer is a high-performance front-loading sterilizer with a 24L capacity. It incorporates flexibility and ease of operation, ensuring reliable laboratory applications...
Portable Steam Sterilizer PS2052
Portable Steam Sterilizer has an 18 L capacity and is controlled by a microprocessor unit. The unit operates at a temperature range of 126°C and a pressure range of 0.14-0.16MPa for a ti...
Portable Steam Sterilizer PS2051
Portable Steam Sterilizer has a 24 L capacity and is controlled by a microprocessor unit. The unit operates at a temperature range of 126°C and a pressure range of 0.14-0.16MPa for a tim...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Stainless chamber resists corrosion and is easy to clean.
2. Fast cycles and effective drying improve instrument turnaround.
3. Pre-set programs for liquids, wrapped goods, instruments and waste.
4. Pressure and temperature safety devices protect operators.
5. Quiet operation and heat-insulated panels suit busy work areas.
FAQ
What is the Steam Sterilizer mainly used for?
The Steam Sterilizer is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.
Which standards and regulations apply to the Steam Sterilizer?
The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.
What does the warranty cover?
We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.
Will staff need special training?
Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Are the consumables universal or proprietary?
Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.
Can the Steam Sterilizer be customised?
A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.
Is installation and commissioning included?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What should be avoided when using the Steam Sterilizer?
Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.