Introduction

Horizontal offers a spacious 360L chamber and a robust double-door design to ensure maximum contamination control. It incorporates a 7.0-inch color touchscreen and built-in printer for real-time monitoring, and record-keeping. With adjustable sterilization and drying time, it allows flexibility for diverse load types. It ensures durability, safety, and a compact design, ideal for modern labs and sterile processing settings.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is suitable for sterilizing items that are resistant to high temperatures and pressures, including both unwrapped and wrapped instruments, surgical dressings, rubber materials, liquids, implantable instruments, porous items, and hollow instruments.

Specifications

Chamber Capacity 360 Liters
Door Type Double Door
Control System + + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 20 kg
Water Consumption per Cycle 160 kg
Power Consumption 32 kW
Chamber Size (W × D × H) 610 × 610 × 1000 mm
Outer Dimensions (W × D × H) 1290 × 1850 × 1350 mm
Net Weight 870 kg

Features

Large Chamber Capacity

Double-Door Design 

+ System 

Built-In Printer

Wide Working Temperature and Pressure Range

High Temperature and Pressure Accuracy

Pre- And Post-Vacuum Cycles 

Adjustable Sterilization and Drying Time

Efficient Steam and Water Consumption

High Power Performance 

Lab-Friendly Design

FAQs

1. What is the recommended sterilization cycle for different types of laboratory materials?

The recommended cycle depends on the material type: 1) For glassware and heat-resistant materials: 121°C, 15-20 psi, for 15-20 minutes; 2) For liquid media: 121°C, 15-20 psi, for 20-30 minutes (longer for larger volumes); 3) For wrapped instruments: 121°C, 15-20 psi, for 25-30 minutes to ensure steam penetration; 4) For waste materials: 132°C, 30 psi, for 30 minutes for biohazardous waste; 5) For heat-sensitive materials: Use a lower temperature (115°C) for a longer duration (30 minutes) or a specialized cycle if available. Always refer to the material manufacturer's recommendations.

2. How to properly load the autoclave to ensure effective sterilization?

Proper loading is crucial: 1) Place items in a way that allows steam to circulate freely around all surfaces; 2) Avoid overloading the autoclave chamber, leaving at least 2-3 inches of space between items; 3) Stack items with openings facing downward to prevent water accumulation and ensure steam penetration; 4) Use autoclave-compatible containers and avoid sealing them tightly (leave lids loose or use vented caps); 5) Separate different types of materials if possible, especially liquids and solids; 6) Ensure that liquid containers are not filled more than 2/3 full to prevent boiling over.

3. What maintenance procedures are required for the autoclave?

Regular maintenance includes: 1) Draining and cleaning the water reservoir after each use to prevent mineral buildup; 2) Descaling the autoclave monthly (or more frequently in hard water areas) using a recommended descaling agent; 3) Inspecting the door gasket for wear, cracks, or damage and replacing it if necessary; 4) Checking the pressure relief valve and safety interlocks quarterly to ensure proper operation; 5) Cleaning the chamber interior with a mild detergent after each use; 6) Performing annual calibration of temperature and pressure gauges by qualified personnel; 7) Keeping a maintenance log to track all service activities.

4. How to troubleshoot if the autoclave fails to reach the desired temperature or pressure?

If temperature/pressure issues occur: 1) Check if the water level in the reservoir is sufficient; 2) Verify that the door is properly closed and sealed (check gasket for damage); 3) Inspect the heating element for signs of malfunction; 4) Check the pressure relief valve to ensure it is not stuck open; 5) Clean the steam vents and drains to remove any blockages; 6) Ensure the autoclave is properly grounded and the power supply is stable; 7) If the problem persists, do not use the autoclave and contact technical support immediately, as it may pose a safety risk.

5. What safety precautions should be followed when operating the autoclave?

Important safety precautions: 1) Never open the autoclave door while it is pressurized or during the sterilization cycle; 2) Allow the autoclave to cool down and depressurize completely before opening; 3) Wear heat-resistant gloves and eye protection when handling hot items; 4) Stand to the side of the autoclave when opening the door to avoid steam burns; 5) Never autoclave incompatible materials (such as volatile solvents, oils, or explosives); 6) Regularly test the autoclave's performance using biological indicators (spore tests) to ensure effective sterilization; 7) Familiarize yourself with the emergency stop procedures and location of safety devices.

1. What are the key features that make the Horizontal Laboratory Autoclave suitable for high-volume sterilization in modern labs?

The Horizontal Laboratory Autoclave is engineered for demanding sterilization tasks, offering a spacious 360-liter chamber capacity and a robust double-door design, which enhances contamination control in sterile environments. Its + system, combined with a 7.0-inch color touchscreen and built-in printer, allows real-time monitoring and precise documentation of every sterilization cycle. The adjustable sterilization and drying time ensures flexibility for various types of load items, while its pre- and post-vacuum cycles improve penetration in porous and hollow materials. These features make it highly efficient and suitable for medical, research, and pharmaceutical laboratories.

2. How does the dual-door design of the Horizontal Laboratory Autoclave enhance safety and infection control?

The double-door design of the Horizontal Laboratory Autoclave plays a crucial role in minimizing cross-contamination risks by separating loading and unloading zones, commonly used in cleanroom environments. This configuration ensures that sterilized items do not come into contact with non-sterile surfaces, thus maintaining sterile integrity. It is especially vital in healthcare and pharmaceutical settings where infection control and clean workflows are essential.

3. What control systems are integrated in the Horizontal Laboratory Autoclave , and how do they aid in user convenience and operational efficiency

The is equipped with an advanced + control system that offers intuitive operation through its 7.0-inch color touchscreen interface. The built-in printer records all sterilization data, which supports audit trails and compliance with regulatory requirements. Users can easily adjust parameters like temperature, sterilization time, and drying time. The intelligent system ensures stable operation, automated cycles, and consistent performance, reducing manual errors and enhancing productivity.

4. Can the Horizontal Laboratory Autoclave handle a wide range of sterilization loads?

Yes, the Horizontal Laboratory Autoclave is specifically designed to accommodate a wide range of sterilization loads including wrapped and unwrapped surgical instruments, medical dressings, rubber goods, liquids, implantable instruments, porous materials, and hollow instruments. Its pre- and post-vacuum capability, high temperature tolerance (105°C to 139°C), and flexible time settings (up to 999 minutes for sterilization and drying) make it suitable for sterilizing complex and varied items.

5. What safety and accuracy features are built into the Horizontal Laboratory Autoclave ?

Safety and precision are top priorities in the . It includes a safety valve that opens at 0.28 MPa, ensuring safe pressure release under abnormal conditions. The autoclave also maintains temperature control accuracy within ± 0.2°C and temperature equilibrium within ± 0.5°C, supporting consistent sterilization results. Additionally, the design temperature is set at 150°C, providing ample margin for high-heat applications without compromising structural integrity.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.