Introduction
An operating table is a medical table used for the positioning of the patients during the surgical procedures, and it is used in the hospitals, the clinics, and the surgery centers for the general and the specialized surgeries. The operating table consists of a table with the adjustable height, the tilt, the trendelenburg and the reverse trendelenburg positions, and the head, the back, and the leg sections, a mattress or a pad, and the controls, and it provides the positioning of the patient for the surgical access, with the features such as the electric or the manual adjustment, the locking, and the accessories, such as the arm boards and the leg holders; the operating table is used for the positioning of the patient during the surgery, for the adjustment of the height and the position for the surgical access, for the procedures in the various surgical specialties, for the patient safety and the comfort, and for many other applications, and it is available in various types, from the general-purpose tables to the specialized tables, such as the orthopedic, the urological, and the neurosurgical tables, and from the manual to the electric and the hydraulic tables; the operating table is an essential equipment in the operating rooms. Operating tables are used in the hospitals, in the surgery centers, in the clinics, and for many other applications. With their positioning, operating tables are essential for the surgical procedures.
Operating Table LOPT-T2010
Operating Table offers optimal height adjustment from 530mm to 780mm. It provides an adjustable head section of 100mm range for optimal patient positioning. This table comes with a built...
Operating Table LOPT-T2012
Operating Table features a 360° flexibility for rotating, detaching, or adjusting the leg section for optimal patient positioning. The table provides a head and leg section tilt of up t...
Operating Table LOPT-T2010
Operating Table provides back section positioning that can raise to ≥45° and lower to ≥20° for optimal patient access. It also provides a kidney bridge elevation of ≥100mm, enhancin...
Operating Table LOPT-T2011
Operating Table features an advanced positioning that includes Trendelenburg (≥20°) and reverse Trendelenburg (≥30°) for ultimate flexibility. It provides an adjustable height of 800...
Standards
IEC 80601-2-46-Medical electrical equipment-Operating tables-Particular requirements
Complies with the above standards, but is not limited to them.
Features
1. Operating table for versatile, motorized or manual positioning of patients during surgical procedures.
2. Multi-function surgical table with adjustable height, tilt, and section positions for various surgical specialties.
3. Suitable for operating rooms, surgery centers, hospitals, clinics, veterinary and outpatient procedure rooms.
4. Includes table base, column, tabletop sections, controls (hand/foot), mattress, accessories and operation manual.
5. Supports patient positioning for general surgery, orthopedics, gynecology, urology, ENT, imaging and outpatient procedures.
FAQ
Q1: What testing scenarios is this table mainly applied to?
A: The operating table is used in hospital operating rooms, ambulatory surgery centers, clinics, veterinary hospitals, and procedure rooms to provide stable, adjustable positioning of patients during surgical and diagnostic procedures, allowing the surgical team to adjust table height, tilt (Trendelenburg/reverse), lateral tilt, and individual section positions (head, back, leg) for optimal surgical access, patient safety, and ergonomic working conditions. It supports general surgery (abdominal, gastrointestinal, laparoscopic, hernia repair - supine, Trendelenburg/reverse Trendelenburg for organ access), orthopedics (joint replacement (hip, knee), fracture fixation, arthroscopy, spine surgery - specialized orthopedic extensions/traction, lateral/supine/prone positioning), gynecology (hysterectomy, ovarian surgery, cystoscopy - lithotomy with stirrups, Trendelenburg), urology (TURP, nephrectomy, cystoscopy - lithotomy, Trendelenburg, imaging-compatible for fluoroscopy), ENT (tonsillectomy, sinus surgery, ear surgery - sitting/reclined with head support, shoulder roll), ophthalmology (eye surgery - supine with head rest, slight reverse Trendelenburg), cardiothoracic (open heart, lung surgery - supine with arms tucked, lateral for thoracic), neurosurgery (craniotomy, spinal surgery - prone/supine/sitting with head fixation (Mayfield clamp)), bariatric surgery (high-weight-capacity table for obese patients), interventional radiology/imaging (fluoroscopy-guided procedures, pain management - carbon fiber tabletop for X-ray transparency, low base for C-arm), outpatient procedures (endoscopy, dermatology, plastic surgery, dental surgery - supine/reclined), and veterinary (animal surgery - similar positioning, may require specialized/veterinary-specific tables).
Q2: What standards does the table comply with?
A: The operating table follows relevant IEC, ISO, AAMI and GB/T standards including IEC 60601-1 (medical electrical equipment safety - general requirements), IEC 60601-2-46 (particular requirements for operating tables), ISO 12143 (operating tables - requirements and test methods), IEC 62353 (medical electrical equipment - periodic testing after repair/refurbishment or before use), AAMI standards (if applicable), and GB/T standards for operating tables. The table is a Class I medical device (FDA, CE MDR, NMPA) and must comply with medical device regulations. Calibration/verification includes: load capacity testing, position accuracy (height, tilt, section angles), electrical safety (grounding, leakage current per IEC 62353), and functional testing of all controls. For hospital use, follow biomedical engineering preventive maintenance schedules and Joint Commission/CMS requirements.
Q3: What is the warranty period for the whole table and key components?
A: The whole operating table is covered by a 12-24 month warranty (medical devices often have 2-year warranty). The base, column, drive system (motor/hydraulic), tabletop sections, controls, and frame are covered, while mattress (wear part - replace every 2-5 years or when damaged), hand/foot controls (wear/damage), batteries (if battery backup - replace every 3-5 years), and accessories (stirrups, arm boards, straps) are consumables or accessories. Damage from improper use, exceeding weight capacity, liquid spillage (corrosion of motors/electronics - clean promptly), impact damage (from carts/equipment), drive system failure, or unauthorized repair is excluded. Extended warranty and service contracts (preventive maintenance, calibration) are standard for medical equipment and may be available. Drive systems have long lifespan (10-20 years with proper maintenance).
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained surgical and anesthesia personnel. Initial training is provided by manufacturer during installation; ongoing competency training per hospital policy. We provide operation manuals and training. Proper table setup (inspect before use: verify all movements function, no unusual noise, table stable, mattress intact, controls responsive; check power cord and battery backup; engage brakes before patient transfer; verify weight capacity (do not exceed - bariatric patients need high-capacity table), patient transfer (transfer from stretcher with proper body mechanics and transfer aids (slide board, lift); apply safety straps; position patient with alignment (avoid pressure points: heels, sacrum, elbows, occiput - use padding/gel pads; pressure injury prevention for long procedures), positioning (use hand/foot control to adjust: height (for surgeon ergonomics - typically 70-110 cm), Trendelenburg/reverse Trendelenburg (head down/up for abdominal/pelvic access - typically 10-30 degrees; ensure patient secured with straps/padding to prevent sliding), lateral tilt (left/right for lateral access - typically 10-20 degrees), table sections (head: up/down for head/neck/anesthesia access; back: up/down for sitting/lateral/lumbar flexion; leg: split/straight for lithotomy/vascular; center: removable for imaging/perineal access), use appropriate accessories (stirrups for lithotomy (adjust height/angle, pad legs - candy cane vs boot type; arm boards (protect arms, avoid abduction >90 degrees to prevent brachial plexus injury); head rest/head fixation (neurosurgery/ENT); padding (gel pads, foam for pressure points); safety straps (secure, not too tight)), anesthesia coordination (communicate with anesthesia team before moving patient (especially Trendelenburg, lateral, prone - can affect blood pressure, ventilation, airway); ensure IV lines, airway, monitoring cables are not kinked/disconnected during positioning), during procedure (lock controls (some tables have lock function to prevent accidental movement); do not move table without communicating with surgical team (can disrupt sterile field, cause injury); monitor patient position/pressure points periodically (for procedures >2 hours, reposition or relieve pressure if possible), post-procedure (return table to neutral (flat, level), lower for transfer, apply straps, transfer to stretcher with anesthesia team and proper body mechanics), clean/disinfect (between patients: wipe tabletop, mattress, controls with hospital-grade disinfectant (follow manufacturer - some materials sensitive to certain disinfectants); remove and clean accessories separately; inspect for damage (mattress tears, exposed metal - pressure injury/electrical hazard; replace damaged parts), maintenance (daily: inspect, clean, check battery charge; weekly: test all movements, check hydraulic fluid (if hydraulic), inspect cords; monthly: biomedical engineering PM (load test, electrical safety, calibration); annually: full service by qualified technician (per manufacturer and hospital policy), troubleshooting (table not moving (check power, emergency stop, lock function, hydraulic fluid level; if battery, check charge; call biomedical engineering if persists), uneven movement (air in hydraulic system - cycle through full range to bleed air; if persists, service), leaking fluid (hydraulic oil leak - do not use, call service), controls not responding (check cable connection, try alternate control (hand vs foot), call service), and safety (never leave patient unattended on elevated table (fall risk); always use safety straps; do not exceed weight capacity; do not use damaged table (electrical/mechanical hazard); follow hospital policy for patient positioning and pressure injury prevention; ensure emergency stop is functional and accessible) are important for safe patient care.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Preventive maintenance and performance verification recommended every 6-12 months by qualified biomedical engineering technician (per manufacturer and hospital policy; Joint Commission requires medical equipment maintenance). Verification includes: electrical safety testing (grounding, leakage current per IEC 62353 - annual), load capacity testing (verify table supports rated load with margin - annual or after repair), position accuracy (height, tilt angles, section positions - verify with inclinometer/tape measure; annual), functional testing of all movements and controls (each use + scheduled), battery backup testing (if equipped - verify battery holds charge and supports table movement during power outage; every 3-6 months), hydraulic system inspection (fluid level, leaks, pressure - every 6 months), and mattress inspection (integrity, pressure distribution - each use; replace every 2-5 years). For accredited hospitals (Joint Commission, DNV, ISO 9001), follow medical equipment management plan and maintain records (maintenance logs, inspection stickers, repair records, calibration certificates). Operating tables are patient-critical medical devices - regular maintenance is required for patient safety and regulatory compliance.
Q7: Are supporting consumables universal?
A: Mattress (operating table pad - specific to table model/size; types: standard foam, gel overlay, pressure-redistributing, warming mattress; replace every 2-5 years or when torn/damaged), hand/foot controls (replacement - specific to table model), accessories (stirrups (candy cane, boot-type (Yellofin); may be universal or table-specific), arm boards (adjustable, padded - may be universal with compatible clamps), safety straps (universal), head rests, gel pads (universal), positioners (bolsters, rolls - universal), clamps/rails (table-specific for accessory attachment)), batteries (if battery backup - specific to model), hydraulic fluid (if hydraulic - specific type per manufacturer), and cleaning/disinfectant supplies (hospital-grade disinfectants compatible with table materials) are available from medical supply companies, though mattress, controls, and table-specific accessories are manufacturer-specific (use OEM or certified compatible parts to ensure safety and warranty). Long-term consumable cost includes mattress replacement (periodic), accessories, and service contracts.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes tabletop material (radiolucent carbon fiber (for X-ray/fluoroscopy imaging - essential for imaging-guided surgery; more expensive), radiolucent polymer (lower cost, adequate for basic imaging), stainless steel (durable, easy to clean, but not X-ray transparent - for non-imaging procedures)), tabletop sections (standard 4-section (head, back, seat, leg), 5-section (more positioning flexibility), split leg sections (for lithotomy/gynecology), removable center section (for perineal access/imaging), head section (adjustable/removable for anesthesia access)), weight capacity (standard 200-250 kg (440-550 lbs), bariatric 300-500 kg (660-1100 lbs) - reinforced frame, wider tabletop), drive system (fully electric (linear actuators - quiet, precise, no hydraulic fluid; modern standard), electro-hydraulic (hydraulic pump driven by electric motor - powerful, smooth, but has hydraulic fluid; older/heavy-duty models), manual (hydraulic foot pump - no power needed, lower cost, for small clinics/outpatient), battery backup (battery-powered movement during power outage - essential for OR safety; battery maintains table position and allows limited movement), control options (hand control (wired/wireless - surgeon/anesthesia control), foot control (hands-free, sterile field use), memory positions (save
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.