Introduction
Microplate Thermo Shaker is a unique design that offers temperature control range from 0°C to 100°C. It offers two heating modes which are automatic and manual, enhancing flexibility for different lab protocols. The shaking speed is adjustable from 200 to 1600 rpm, with a 3 mm orbit for consistent mixing. Its advanced brushless DC motor and intelligent temperature control offers consistent performance and minimal maintenance. Our Microplate Thermo Shaker is widely used in molecular biology, immunology, clinical diagnostics, and pharmaceutical laboratories.
This thermo-shakers is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Microplate Thermo Shaker is used in molecular biology, immunology, clinical diagnostics, and pharmaceutical laboratories. It is ideal for sample incubation, enzyme reactions, catalytic processes, nucleic acid hybridization, and preservation of temperature-sensitive materials. Its multi-plate capacity and precise temperature management make it suitable for assays, cell culture in deep well plates, and other research applications where consistent mixing and thermal control are critical.
Specifications
| Temperature Setting Range | 0°C to 100°C |
| Temperature Control Range | RT +5°C to 100°C |
| Shaking Speed | 200 to 1600 rpm |
| Sample Capacity | 6 microplates or deep-well plates |
| Heating Time | Up to 5 min (from RT 25°C to 60°C) Up to 20 min (from RT 25°C to 60°C) |
| Pre-heating Setting Time | 37°C to 100°C |
| Mixing Orbit | 3 mm |
| Temperature Uniformity | Up to ±0.5°C at 37°C |
| Temperature Accuracy | Up to ±0.5°C at 37°C |
| Timing Range | 1 min to 99h 59 min |
| Auto Preheating | Yes |
| Auto Resume to Run | Yes |
| Pause Function | Yes |
| Auto Fan Function | Yes |
| Independent Timing Function | Yes |
| Multi-point Running | Yes (max 5 points) |
| Multi Cycling | Yes (max 99 times) |
| Heating Lid Temperature Control Mode | Automatic / Manual |
| Display Accuracy | 0.1°C |
| Power Requirements | AC 220 V or AC 110 V, 50/60 Hz, 480 W |
| Dimensions | 481 × 346 × 228 mm |
| Packing Dimension | 580 × 440 × 350 mm |
| Net Weight | 15 Kg |
| Gross Weight | 17 Kg |
Features
Multi-Cycle Programming
Automatic calibration function
Display
Automatic overheat Protection
Low noise
FAQs
1. How many plates and what type of plates does the Microplate Thermo Shaker support?
The Microplate Thermo Shaker is designed to hold up to 6 plates simultaneously, including both standard microplates and deep-well plates. This makes it suitable for high-throughput workflows in diagnostic, research, and pharmaceutical labs. Its flexible plate compatibility allows it to use a variety of plate formats depending on the application. This capacity is ideal for running multiple assays or experiments at once. It saves time and maximizes sample processing efficiency.
2. What automatic features are included in the Microplate Thermo Shaker ?
Microplate Thermo Shaker is equipped with a range of intelligent automatic functions to enhance usability and safety. These include automatic preheating, auto resume after power recovery, automatic fault detection, automatic fan control, and independent timing function. It also supports both automatic and manual lid temperature control, and helps to maintain consistent internal conditions. These features reduce the need for constant monitoring and ensure seamless operation. This makes it a reliable tool for long and unattended experiments.
3. Can each plate in the Microplate Thermo Shaker operate with a different time setting?
Yes, the Microplate Thermo Shaker allows independent timing control for each of the six plates. This feature is highly useful for labs conducting varied experiments on different samples simultaneously. It supports different timing parameters based on the protocols for each microplate. It enhances flexibility and efficiency, especially in multi-assay operations. This function supports more precise and customized workflows.
4. How long can we run an experiment using the Microplate Thermo Shaker ?
The Microplate Thermo Shaker allows experiment durations ranging from 1 minute to 99 hours and 59 minutes, making it suitable for both short procedures and long incubations. This wide timing range ensures compatibility with protocols requiring extended processing times. The independent timer supports multiple cycles and pause-resume functions. This helps maintain continuity even during power interruptions. It’s ideal for experiments requiring long-term thermal and shaking conditions.
5. What safety features does the Microplate Thermo Shaker offer?
The includes several safety features such as built-in hardware and software-based over-temperature protection, automatic fault alerts, and power recovery functions. It ensures safe operation during long runs or unattended use. The wrap-around heating lid helps reduce edge effects and maintains temperature consistency across the plate. Additionally, it alerts users if parameters go out of range. These features make the shaker highly reliable and lab-safe.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.