Introduction

A -86掳C under counter ultra-low temperature freezer provides deep freezing storage for biological samples. It is widely used in laboratories and biobanks. The system ensures long-term preservation. It solves sample degradation risks. By providing compact ultra-low temperature storage, it supports critical sample safety.

暂无信息

Standards

WHO PQS E003/ULT01-Vaccine ultra-low temperature freezers, compression cycle-Specification and verification

IEC 61010-2-011:2019-Particular requirements for refrigerating equipment

IEC 62552-1:2015-Household refrigerating appliances-Characteristics and test methods-Part 1: General requirements

ISO 20387:2018-Biotechnology-Biobanking-General requirements for biobanking

ISO/TS 20388:2021-Biotechnology-Biobanking-Requirements for animal biological material

Complies with the above standards, but is not limited to them.

Features

1. Stable sub-zero temperature control with a digital display and clear setpoint.

2. Data logging option supports temperature traceability and audits.

3. Audible and visual alarms warn of temperature excursions or power failure.

4. High-density foam insulation minimises cold loss and energy use.

5. Adjustable shelves or baskets keep samples organised and accessible.

FAQ

What is the -86?C Under Counter ULT Freezer mainly used for?

The -86?C Under Counter ULT Freezer is used for medium- to long-term storage of samples, reagents, biological materials and specimens at sub-zero temperatures. It serves clinical, diagnostic, research and industrial laboratories that need stable freezing without reaching ultra-low temperature levels.

Which standards and regulations apply to the -86?C Under Counter ULT Freezer?

The unit is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for laboratory freezers. Storage of biological materials should follow applicable laboratory and biobanking guidance. Compliance documentation can be provided on request.

What does the warranty cover?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Is the -86?C Under Counter ULT Freezer difficult to operate?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the -86?C Under Counter ULT Freezer be calibrated?

To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.

Are consumables and spare parts easy to obtain?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Can it be adapted to our requirements?

The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What maintenance and safety points matter?

Flammable materials, pressurised containers and samples needing ultra-low temperatures should not be stored in this unit. Use low-temperature-rated containers, avoid overloading and keep vents clear. Follow laboratory safety regulations.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.