Introduction

Microplate Washer features a residual liquid volume of less than 0.65 µL, ensuring minimal cross-contamination and efficient washing performance. It features an automatic flushing function to prevent clogs and maintain smooth operation. Integrated liquid level monitoring system continuously tracks reagent levels to prevent interruptions. Our Microplate Washer is used for plate cleaning to ensure accurate detection results.

This microplate washer is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Microplate Washer is built for efficient cleaning of microplates used in and other immunoassays. It is widely applied in research labs, quality control, agriculture, and food testing fields.

Specifications

Residual Liquid Less than 0.65µL
Microplates 96 well
Injection Volume Accuracy Less than 2% at 300µL
Applicable Plate Type Flat bottom, U-shaped, V-shaped, C-shaped
Injection Volume CV less than or equal to 1.5 at 300µL
Washing Volume 50uL to 2000uL increment 50µL
Washing Times 1 to 99 times
Soaking and Shaking Time 0 to 99:59 m:s
Shaking Speed Off, slow, medium, fast
Aspiration Time 0 to 99.9s
Aspirate Mode One point, two points, more points
Liquid Injection Coefficient 0 to 2.0
Insufficient Washing Liquid Alarm Yes
Waste Liquid Overflow Alarm Yes
Waste Liquid Discharge Yes
Number of Program Storage 5000
Communication Interface USB2.0,
Fuse 250V, 5A Ф5 ×20
Power Supply AC 220V 50/60Hz
Dimension (W×D×H) 350 × 475 × 180 mm
Weight 11.5 kg

Features

7-inch touchscreen display

Simultaneous soaking and shaking

Three vibration strength levels

Multi-point aspiration modes

Flexible plate cleaning modes

FAQs

1. What types of microplates can the Microplate Washer clean?

Microplate Washer is compatible with a variety of microplate types, including flat-bottom, U-shaped, V-shaped, and C-shaped plates. This versatility allows it to be used in multiple applications such as , cell culture assays, and biochemical testing. The washer’s cleaning head is precisely adjustable to fit different well shapes and sizes, ensuring thorough washing without cross-contamination. This makes it ideal for laboratories handling diverse assay formats. The ability to clean multiple plate types improves workflow efficiency and reduces the need for multiple washing instruments.

2. How does the Microplate Washer improve assay accuracy?

The Microplate Washer enhances assay accuracy by effectively removing residual reagents and contaminants from the wells. It achieves a low residual liquid volume of less than 0.65 ?L per well, which significantly reduces background noise and false-positive results. The washer’s programmable washing cycles and adjustable aspiration modes ensure consistent and repeatable cleaning, minimizing assay variability. This results in more reliable enzyme label analysis and improved overall data quality. Laboratories using the Microplate Washer benefit from increased confidence in their assay outcomes.

3. Can the Microplate Washer handle high-throughput laboratory workflows?

Yes, the Microplate Washer is designed to support high-throughput laboratory environments. It offers fast and customizable washing cycles, with the ability to store up to 500 different washing programs and perform up to 99 cycles per program. Its automatic flushing and liquid level monitoring functions minimize downtime, while the large memory capacity allows quick switching between protocols. The washer’s efficient soaking, shaking, and multi-point aspiration modes further enhance cleaning speed and effectiveness. This makes it well-suited for clinical labs, research centers, and quality control facilities requiring rapid processing of multiple plates.

4. What safety and maintenance features are included in the Microplate Washer ?

Microplate Washer incorporates several safety and maintenance features to ensure reliable operation. It has automatic alarms to notify users when the washing reagent bottle is empty or the waste liquid bottle is full, preventing system damage or contamination. The built-in filter in the washing pipeline reduces the risk of clogging. The detachable needle cleaning heads allow easy maintenance and thorough cleaning of the system. Additionally, the washer supports program updates, helping to maintain optimal performance and compatibility with evolving protocols. These features reduce operator workload and extend equipment lifespan.

5. Is the Microplate Washer easy to operate for new users?

Yes, the Microplate Washer is designed for ease of use, even for operators new to microplate washing. It features a large 7-inch high-definition color touchscreen with a full capacitive touch interface, providing an intuitive and visually clear user experience. Pre-programmed washing protocols and the ability to store custom programs simplify operation. The system supports connectivity for easy importing, exporting, and updating of washing methods. Clear status indicators and alarms further assist users in monitoring the washing process, making training straightforward and reducing user errors.

6. Can the Microplate Washer be integrated into automated laboratory workflows?

Microplate Washer supports integration into automated workflows through its communication interfaces, including 2.0 and connectivity. This enables remote control, data transfer, and system monitoring within laboratory information management systems (). Its ability to store a large number of washing programs and customizable protocols facilitates compatibility with various automation platforms. The precise control over washing parameters ensures reproducibility when used in high-throughput automated environments. This makes the Microplate Washer a suitable component for modern labs aiming to streamline their sample processing.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.