Introduction

Salt Spray Test Chambers operate within a controlled temperature range, providing accurate corrosion testing across various industries. They offer spacious capacities, ensuring effective and reliable salt fog testing. Their independent conical spray towers guarantee precise performance, while customizable spray quantities enable adaptable testing. They feature high-precision nozzles for uniform salt fog dispersion and accurate results. salt spray test chambers are perfect for use in automotive, aerospace, marine, electronics industries, and research labs. Complies with ASTM B117 standard, supports 5% NaCl solution concentration.

Salt Spray Test Chamber T-SSC-S2100

Salt Spray Test Chamber T-SSC-S2100

Salt Spray Test Chamber is a cyclic corrosion test chamber equipped with an LCD digital display, designed in accordance with NFPA 1981 and ASTMB117 standards. It comes with a 480 L capacit...
Salt Spray Test Chamber T-SSC-S2101

Salt Spray Test Chamber T-SSC-S2101

Salt Spray Test Chamber is a cyclic corrosion test chamber equipped with an LCD digital display, designed in accordance with NFPA 1981 and ASTMB117 standards. It comes with a 1000 L capaci...
Salt Spray Chamber T-S225SSC

Salt Spray Chamber T-S225SSC


Salt Spray Chamber provides a 1200L capacity and operates within a temperature range of 5 °C to 50 °C. It is equipped with a PYREX glass precision nozzle to prevent clogging. It support...
Salt Spray Chamber T-S224SSC

Salt Spray Chamber T-S224SSC


Salt Spray Chamber features a 480L capacity and operates efficiently within a temperature range of 5 °C to 50 °C. It features an air-squeezing demist system with a 120° cone-shaped lid...
Salt Spray Chamber T-S223SSC

Salt Spray Chamber T-S223SSC


Salt Spray Chamber operates within a temperature range of 5 °C to 50 °C and has a 108L capacity for precise corrosion resistance testing. It is equipped with a saturated barrel heating ...
Salt spray chamber T-S222SSC

Salt spray chamber T-S222SSC


Salt spray chamber is a 800 L chamber designed for corrosion testing. It comprises of a saline fog environment with a temperature range from (35 °C to 50 °C) and transparent angled (1...
Salt spray chamber T-S220SSC

Salt spray chamber T-S220SSC


Salt spray chamber is a 60 L chamber designed for corrosion testing. It comprises of a saline fog environment with a temperature range from (35 °C to 50 °C) and transparent angled (11...
Salt Spray Chamber T-S221SSC

Salt Spray Chamber T-S221SSC


Salt Spray Chamber has a 270L capacity and operates within a temperature range of 5 °C to 50 °C. It utilizes a PYREX glass precision nozzle, ensuring uniform salt fog dispersion. It fea...

Standards

ISO 9227:2022-Corrosion tests in artificial atmospheres-Salt spray tests

ASTM B117-Standard Practice for Operating Salt Spray (Fog) Apparatus

Complies with the above standards, but is not limited to them.

Features

1. Safety devices protect against over-temperature and over-humidity.

2. Controller supports ramps, dwells and stored test profiles.

3. Data logging and export support traceable test reports.

4. Various sizes and configurations suit small to large products.

5. Forced air circulation delivers uniform conditions in the workspace.

FAQ

What is the Salt Spray Test Chamber mainly used for?

The Salt Spray Test Chamber is used to reproduce temperature, humidity or other environmental conditions for testing product reliability and material behaviour. It supports electronics, automotive, aerospace, polymer, packaging and quality-control laboratories.

Which standards and regulations apply to the Salt Spray Test Chamber?

The chamber is designed with reference to applicable IEC, ISO, ASTM and GB/T environmental-testing standards and IEC 61010 electrical safety. Programs and tolerances must follow the relevant standard. Compliance documentation can be provided on request.

How long is the warranty period?

The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.

Is the Salt Spray Test Chamber difficult to operate?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Salt Spray Test Chamber be calibrated?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Are the consumables universal or proprietary?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Are options or configurations available?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Is installation and commissioning included?

Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.

What should be avoided when using the Salt Spray Test Chamber?

Do not place wet, corrosive or explosive loads, exceed weight or temperature limits or block airflow. Use conditioned specimens and proper fixturing. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry