Introduction

Micro Centrifuge delivers maximum of 21,380×g with 10×g increments, ensuring precise centrifugal control. Its advanced digital control panel allows easy speed adjustments and real-time monitoring of operations. Equipped with brushless DC motor ensures low noise, minimal vibration, and extended operational lifespan. Feature user-friendly interface simplifies operation, reducing manual errors and enhancing experimental accuracy. Offers multi-layer insulation reduces temperature fluctuations, protecting heat-sensitive samples effectively.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Our Micro Centrifuge ensures precise and efficient separation of biological and chemical samples in research, diagnostics, and laboratory workflows, offering high-speed performance, user-friendly operation, and enhanced safety features.

Specifications

Max. Speed 15,000 (200 to 15,000 rpm) in 100rpm increment
Max. 21,380×g, step: 10×g
Rotor Capacity 1.5/2mL × 24, 0.2/0.5ml × 36, -8 strips × 4, 5 ml × 12,5ml × 18
Temperature Setting -20℃ to 40℃
Noise Level ≤56dB
Run Time 30sec to 99min; (continuous running)
Acceleration and Deceleration Increase-25s and Decrease-25s
Motor Type Brushless DC motor
Power Supply Single-phase 100 to 120V/200 to 240V, 50Hz/60Hz.500W
Dimension (D×W×H) 332mm×553mm×283mm
Weight 30 kg

Features

Electronic magnetic door lock system 

Automatic precooling system 

End-of-run sound indicator 

Wide temperature range 

Fast pre-cooling time 

Program storage capacity 

Sealed rotor design

High-strength aluminum alloy rotor 

Rotor imbalance detection 

Adjustable acceleration/deceleration 

Supports multiple tube sizes

External condensation tank

Rotation speed/ switchover

Inching operation, running process indicator, sound alert

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.