Introduction

An ICP mass spectrometer (ICP-MS) is an analytical instrument that combines inductively coupled plasma (ICP) with a mass spectrometer, used for the trace and ultra-trace elemental analysis of samples, and it is one of the most sensitive analytical instruments, used in environmental, geological, clinical, food, and many other fields. The ICP-MS ionizes the sample in an inductively coupled plasma, which is a high-temperature plasma generated by an induction coil, and the ions are extracted into the mass spectrometer, where they are separated by their mass-to-charge ratio and detected, and the instrument provides the concentration of the elements in the sample, with a very high sensitivity, capable of detecting elements at concentrations in the parts per trillion range; the ICP-MS can analyze many elements simultaneously, and it provides the isotopic ratios, and it is used with various sample introduction systems, including liquid nebulizers, laser ablation for solid samples, and chromatography for speciation analysis, and it provides rapid and accurate results, with features such as automated operation and data management; the ICP-MS is used for the analysis of trace metals in environmental samples, for the analysis of elements in food and beverages, for the analysis of metals in clinical samples, for the analysis of geological materials, for the analysis of semiconductors and electronics, and for many other applications. ICP-MS instruments are used in environmental laboratories, in the food industry, in the pharmaceutical industry, in the semiconductor industry, in geological research, in clinical laboratories, and in many other applications. With their ultra-trace sensitivity, ICP-MS instruments are essential for elemental analysis.

ICP Mass Spectrometer LICM-T2010

ICP Mass Spectrometer LICM-T2010



Mass Spectrometer operates over a wavelength range of 0.00916 nm to 0.103 nm, allowing for precise elemental analysis. It is designed to analyze mass ranges from 2 to 255 amu to detect ...

Standards

EPA Method 6020B-Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

Complies with the above standards, but is not limited to them.

Features

1. ICP mass spectrometer for ultra-trace elemental analysis.

2. Inductively coupled plasma mass spectrometer with detector and software.

3. For environmental, food, pharmaceutical and research laboratories.

4. Includes ICP-MS, sampler, software, accessories and manual.

5. Quantifies elements and isotopes at very low concentrations.

FAQ

Q1: What scenarios is this spectrometer used for?

A: It quantifies multiple elements and isotopes at ultra-trace levels in environmental, food, pharmaceutical and research samples using inductively coupled plasma mass spectrometry.

Q2: What standards does it comply with?

A: It follows EPA 200.8 and 6020, ISO 17294 and related GB/T standards, with calibration using traceable standards and interference control.

Q3: What is the warranty?

A: The instrument carries a 12 to 24 month warranty covering the hardware and controls. Consumables include cones, torches and gases. Damage from misuse is excluded.

Q4: Is it hard to operate?

A: Operation requires trained analysts for sample preparation, tuning, interference correction and maintenance. We provide a manual, installation and training.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.

Q7: Are consumables universal?

A: Cones, torches and gases are model-specific or standard industrial supplies. Ongoing cost includes argon, cones and maintenance.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include collision/reaction cells, autosamplers, laser ablation and data compliance software. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: Standard delivery includes the system and manual. On-site installation, calibration and training are typically included or required.

Q10: What samples are compatible?

A: It handles digested, dissolved or properly prepared samples within matrix and concentration limits. It is not for undigested solids without accessories, high dissolved solids beyond tolerance, or non-elemental analysis.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.